4) Disassembly of freezer air duct cover plate:
1. Insert the lower air outlet of the upper freezer air duct by hand and pull it out slightly to avoid the air duct clip breaking;
2. Pull out the left terminal by hand and take out the upper cover plate of air duct;
3. Remove the screws of air duct assembly with a cross screwdriver, and remove the rear cover plate of the air duct;
4. Use a cross screwdriver to remove the three screws of the fan and replace the fan;
5. During installation, please see to it that the buckle be embedded as shown in the figure to prevent air leakage.
Insert your hand into the air
outlet and pull it out
Содержание TRF-520WEXA+
Страница 1: ...Refrigerator Service Manual TRF 520WEXA TCL Home Appliances HeFei Co Ltd ...
Страница 5: ...Product appearance ...
Страница 8: ...2 Exploded View of Product Structure ...
Страница 11: ...3 Product operation rules The TRF 520WEXA display panel is as follows ...
Страница 15: ...Technical Parameters ...
Страница 19: ...Electric control 1 Electrical Control Circuit Diagram ...