Air Conditioner Service Manual
31
9. Installation manual
9.1 Installation Details
Connecting pipe length
Model
Pipe size(Inch)
Liquid
Gas
TCE-25CHSD
1/4
3/8
TCE-35CHSD
1/4
3/8
TCE-51CHSD
1/4
1/4
TCE-70CHSD
1/4
1/2
Mode
Standard
length: m
Refrigerant piping
Max. length: m
A
Additional refrigerant B
Calculation: ×g=Bg/m(A-5m)
TCE-25CHSD
5.0
25
20g/m
TCE-35CHSD
5.0
25
20g/m
TCE-51CHSD
5.0
25
30g/m
TCE-70CHSD
5.0
25
30g/m
Connecting cables
The power cord should be selected according to the following specifications sheet.
Appliance Amps
Wire Size
5
AWG21/0.75 mm2
10
AWG18/1.0 mm2
13
AWG15 /1. 5 mm2
18
AWG14/1.6 mm2
25
AWG12/2.0 mm2
30
AWG10/2.5 mm2
Outdoor unit
Pipe length is 25
meters Max.
H
ei
ght
sh
ou
ld
be
less
tha
n
10m
Indoor unit
Outdoor unit
Pipe length is 25
meters Max.
Indoor unit
H
ei
ght
sh
ou
ld
be
less
tha
n
10m