11.3.3 Display E3, E7
Reasons:
1) Outdoor pipe temp sensor, outdoor temp sensor & exhaust temp sensor connection terminal loose or not
plugged in.
Solution:
Check the connecter of sensor and slot, if loose or not plugged in, please connect again.
2) Outdoor pipe temp sensor, outdoor temp sensor & exhaust temp sensor damage (short or broken).
Solution:
Check and replace the sensor.
3) Outdoor PCB damage.
Solution:
Check and replace the outdoor PCB.
11.3.4 Display E8
Reasons:
1) Outdoor discharge pipe temp sensor connection terminal loose or not plugged in.
Solution:
Check the connecter of sensor and slot, if loose or not plugged in, please connect again.
2) Outdoor pipe temp sensor damage.
Solution: Check and replace the sensor.
3) Outdoor PCB damage.
Solution: Check and replace the outdoor PCB.
11.3.5 Display E0,E5
Reason
: Indoor / outdoor communication damage.
Solution:
1) Check if the indoor and outdoor connections are correct. The terminal L and N which connect to indoor
unit shall correspond to each other on indoor and outdoor units. Measure the voltage on outdoor
Fail
OK
Fail
OK
Содержание TACM2O-28HIA
Страница 14: ...Air Conditioner Service Manual 13 6 Wiring diagram INDOOR UNIT Wall split type Cassette Duct type...
Страница 15: ...Air Conditioner Service Manual 14 OUTDOOR UNIT ONE TO 2 TYPE ONE TO 3TYPE...
Страница 16: ...Air Conditioner Service Manual 15 ONE TO 4 TYPE...
Страница 23: ...Air Conditioner Service Manual 22 CASSETTE TYPE INDOOR UNIT...
Страница 30: ...Air Conditioner Service Manual 29 OUTDOOR UNIT 10 11 12 8 9 7 6 5 17 13 14 16 15 19 18 20 21 23 4 3 2 1 22 24...