TCL Air Conditioner Service Manual
5
Model No. TAC-24CS/
K
TAC-24CHS/
K
Type
Cooling Only Heating Pump
Control type Remote Remote
Rated cooling capacity Btu/h 24,000 24,000
Rated heating capacity Btu/h N/A 26,
000
EER for cooling
Btu/h.w
9.0 9.0
COP for heating W/W N/A 2.55
Moisture
removal Liters/h
2.2 2.2
High
dB(A)
47 47
Med.
dB(A)
44 44
Indoor noise level at
cooling
Low
dB(A)
40 40
Outdoor
noise
level
dB(A)
58 58
Electrical Data
Power supply
220-240V~/50Hz
Voltage
Range V
Cooling A 13 13
Rated current
Heating A N/A 13.8
Cooling
W
2600 2600
Rated input
Heating W N/A 2800
Refrigerating System
Refrigerant/Charge Gram
R22/2500g R22/2500g
Type Rotary Rotary
Model ------------------ -----------------
LRA
A ------ -------
Compressor
MFG ----------------- -----------------
Evaporator
Louver fin and Grooved tube type (
φ
7)
Condenser
Corrugated fin and Grooved tube type (
φ
9.53)
Expansion device
Capillary tube
Defrosting system
Microcomputer controlled reverse system
Fan System
Indoor air circulation
m
3
/h
1000 1000
Indoor fan type
Cross flow Cross flow
Cooling rpm 1300/1200/1100 1300/1200/1100
Heating
rpm N/A
1300/1200/1100
Dry rpm 1000 1000
Indoor fan speed
H/M/L
Sleep rpm 1000 1000
Indoor fan motor output W 35 35
Outdoor air circulation
m
3
/h
--- ---
Outdoor fan type Propeller fan Propeller fan
Outdoor
fan
speed rpm
850 850
Outdoor fan motor output W 110 110
Connections
Refrigerant coupling
Flare type
Gas
Inches
5/8 5/8
Connecting Pipe
Liquid
Inches
3/8 3/8
Connecting Wiring
Size
×
Core
number
Drainage Pipe
O.D 16mm
Others
Suitable area m
2
35~48 35~48
Indoor mm 1036
×
313
×
204 1036
×
313
×
204
Net dimensions
(W x H x D) Outdoor mm 890
×
307
×
660 890
×
307
×
660
Indoor
kg
16 16
Net weight
Outdoor
kg
57 60
Indoor mm 1103
×
395
×
280 1103
×
395
×
280
Packing dimensions
(W x H x D) Outdoor mm 990
×
405
×
705 990
×
405
×
705
Indoor
kg
20 20
Gross weight
Outdoor
kg
63 65
Loading Capacity 40’/40’HC 66/142/162 66/142/162
Note:
The technical specifications is only reference.