SAFETY INSTRUCTIONS                                                                                                                 

 
IMPORTANT! 

  Carefully read the instructions before operating the unit 

  This  appliance  comprises  of  two  indoor  units  and  an  outdoor  unit.  The  indoor  slim 

evaporators  are  designed  exclusively  for  indoor  installations  while  the  external 
condenser can be installed outside while still away from flood water or snow line. 

  Always place the unit on a dry and stable surface. Install the outdoor unit on a wall with 

wall-mounting  brackets  or  fix  to  a  floor  slab  with  special  floor  mounting  slab  bolts  or 
brackets away from flood or snow lines. 

  Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed power source. 

  Installation must be in accordance with the regulations of the country where the unit is 

used.  

  This appliance is intended for permanent installation into a fixed structure, and should 

not be installed on vehicles.  

  The  outdoor  part  of  the  air  conditioner  unit  must  always  be  stored  and  transported 

upright, otherwise irreparable damage may be caused to the compressor; if in doubt we 
suggest waiting at least 24 hours before starting the unit. 

  These  air  conditioners  are  supplied  with  pre  flared  refrigeration  pipes  and  electrical 

cables, which enables the installer to reduce the installation time.  

  European  Union  regulations  requires  for  an  F-Gas  trained  engineer  to  handle  any 

operation  where  non-qualified  intervention  could  cause  fluorinated  gas  to  escape.    A 
commissioning certificate must be issued with any installation. 

  This air conditioner contains R32 which is a safe efficient refrigerant which has a lower 

environmental burden than traditional refrigerants. 

  The  refrigerant  used  in  this  air  conditioner  is  an  environmentally  friendly  hydrocarbon 

R32,  which  has  a  very  low  Global  Warming  Potential  compared  to  traditional 
refrigerants. 

  R32 is classed as slightly flammable and as such naked flames and sources of ignition 

should be kept a safe distance from the unit.

  If  you  are  in  any  doubt  about  the  suitability  of  your  electrical  supply  have  it  checked 

and, if necessary, modified by a qualified electrician. 

  This air conditioner has been tested and is safe to use. However, as with any electrical 

appliance - use it with care. 

  Disconnect the power before dismantling, assembling or cleaning.  

  Never connect the unit to an electrical outlet using an extension cord. Both the indoor 

unit and outdoor must be hardwired by a qualified electrician.  

  Never  operate  this  appliance  if  the  cord  is  damaged.  Ensure  the  power  cord  is  not 

stretched or exposed to sharp objects or edges. 

  A  damaged  supply  cord  should  be  replaced  by  the  manufacturer  or  a  qualified 

electrician in order to avoid a hazard. 

  Avoid touching any moving parts within the appliance. 

  Never insert fingers, pencils or any other objects through the guard  

  This  appliance  is  not  intended  for  use  by  persons  (including  children)  with  reduced 

physical, sensory or mental capabilities. It is also not intended for use by those with a 
lack  of  experience  and  knowledge,  unless  they  have  been  given  supervision  or 
instruction concerning the use of the appliance by a person responsible for their safety.  
Do not leave children unsupervised with this appliance. 

Содержание iQool-2MS9K9K

Страница 1: ...l 2MS12K12K iQool 2MS12K12KB 2 x 12 000 BTU Indoor SMART WIFI CONTROLLED WALL MOUNTED INVERTER MULTI SPLIT AIR CONDITIONER WITH HEAT PUMP Thank you for choosing a TCL Air Conditioner Please read this...

Страница 2: ...A DEVICE 15 CONNECTING USING CF MODE QUICK CONNECTION 16 CONNECTING USING AP MODE ALTERNATIVE METHOD 17 USING THE TIMER FUNCTION 20 MORE SETTINGS 21 MAINTENANCE 22 END OF SEASON 23 START OF SEASON 23...

Страница 3: ...conditioner contains R32 which is a safe efficient refrigerant which has a lower environmental burden than traditional refrigerants The refrigerant used in this air conditioner is an environmentally f...

Страница 4: ...any variance between the manual and the product received the information provided on the product should be followed ENERGY SAVING AND UNIT SAFETY PROTECTION TIPS Do not cover or restrict the airflow f...

Страница 5: ...ne 5 Liquid line 6 Compressor 7 Condenser 8 Condenser Fan HEAT PUMP MODE The system operates in reverse the condenser works as an evaporator the evaporator as a condenser warm air is blown into the ro...

Страница 6: ...Display 5 Signal receiver 6 Terminal block cover 7 Ionizer generator not applicable on all models 8 Deflectors 9 Emergency button 10 Indoor unit rating label 11 Airflow direction louver No Description...

Страница 7: ...5 Timer Press to set the timer 6 Sleep Press to activate the SLEEP function 7 Eco In cooling mode press to increase the set temperature by 2oC In heating mode press to decrease the set temperature by...

Страница 8: ...ence between the set temperature and the room temperature SETTING UP THE REMOTE When batteries are first inserted into the remote or following changing the batteries the remote must be set up for COOL...

Страница 9: ...e best performance The operation logic is as below Ambient Temperature Operation Mode Auto Temperature 20 C Heating 23 C 20 C 26 C Dry 18 C 26 C Cool 23 C 3 Use the FAN button to set the fan speed TIM...

Страница 10: ...15 minutes before returning to their previously set levels SWING 1 Press the SWING buttons to control the fan direction 2 The controls the horizontal air movement up down 3 The button is not activate...

Страница 11: ...se of the room where the air conditioner is installed Strong sunlight and the presence of people lights or equipment creates an additional heat load Normal living spaces require about 350 Btu per squa...

Страница 12: ...ir conditioner requires a good signal during the setup process Your air conditioner is designed to be connected to a 2 4ghz network and the connection is set up using the TCL SMART LIFE app We would a...

Страница 13: ...ill need to be registered Click on the Register button to enter the registration screen The account can be created by using either the default option of an email address or alternatively by SMS messag...

Страница 14: ...our new password in the box below Please note the password should be at least 6 characters and include letters and numbers Then press the confirm button to log in FORGOTTEN PASSWORD Should the passwor...

Страница 15: ...e device within the app and as such the following connection process should be repeated for each indoor unit CHANGING BETWEEN CONNECTION TYPES To change the unit between the two connection types quick...

Страница 16: ...your Wifi router from the drop down list and enter the password Please note the password is case sensitive before pressing next The app will automatically upload the connection information to the air...

Страница 17: ...isplayed 2 Press on the AP Mode button in the top right of the screen to change the app to AP mode connection 3 Select your Wifi router from the drop down list and enter the password Please note the p...

Страница 18: ...itioner once the connection is completed a message will be displayed to confirm On this page there is the option to rename the air conditioner to something more relevant If the connection fails please...

Страница 19: ...e desired temperature The tabs on the bottom of the screen should be used to change other settings Mode Allows the operating mode to be changed between Feel Heat Dry Cool and Fan Speed Allows the fan...

Страница 20: ...e bottom of the screen If there is a timer already programmed that you would like to amend press and hold the timer which requires amendment OFF TIMER 1 Select Timer Off 2 Set the time the air conditi...

Страница 21: ...the main screen the three dots in the top right hand corner give you access to the settings options for the app This a number of extra options for modifying the name of the air conditioner and removi...

Страница 22: ...ry dirty it may be washed in lukewarm water with a very small amount of neutral detergent Rinse well and allow to dry completely not in direct sunlight or near a source of heat 3 Keep the front panel...

Страница 23: ...lled within the indoor unit and is clean Check that the condensation outlet drains properly and there is no dirt or organic blockage otherwise leakage may occur Install 2 AAA batteries in the remote c...

Страница 24: ...age and frequency This unit is only suitable for an earthed electrical supply connection voltage 230 V 50 Hz The information specifications and parameter are subject to change due to technical modific...

Страница 25: ...utside of direct sunlight or strong winds which is not on a flood line and where noise and airflow does not cause interference or inconvenience Select a location where there are no obstructions to the...

Страница 26: ...26 RECOMMENDED INSTALLATION SPACING DIAGRAM...

Страница 27: ...it Level Number 14 7mm Masonry Drill Pencil and Chalk 1 5 inch number 10 screws Small Stepladder 7mm Wall Plugs Protective Glasses and Mask Pipe and Cable Detector 4 inch Plastic Ties 2 Inch Pipe Clip...

Страница 28: ...rest of the holes and insert the wall plugs 8 Fix the backplate to the wall 9 Mark the hole centre and make sure the cutter will clear the backplate 10 Drill the hole at a slight downwards angle When...

Страница 29: ...Insert the piping hole sleeve into the hole to prevent the connecting piping and wiring from been damaged when passing through the hole The piping can be lead out on the right left or directly behind...

Страница 30: ...unit horizontally Use expansion bolts to fix the mounting supports on the wall Use bolts and nuts to fix the outdoor unit firmly on the supports and keep on the same level If the unit is installed on...

Страница 31: ...outdoor units and the connecting pipe 2 Align the joint of the connecting pipe between the indoor and outdoor and tighten the connecting nut by hand to prevent cross threading Secure them with a wrenc...

Страница 32: ...ank caps of the 2 way and 3 ways valves applying the torque listed in the table above ADDING REFRIGERANT Refrigerant must be added if the pipe length is more than 5 metres 16 5 This operation can only...

Страница 33: ...ake the packed soft pipes vertical before extending Please do not extend only one side of the packed soft pipes Please make use of semicircle pulley to keep the allowed bending angle Extreme bending c...

Страница 34: ...e the unit and invalidate the warranty Secure the wires and replace the cover before operating the unit The appliance should be installed in accordance with national wiring regulations If the supply c...

Страница 35: ...GRAMS Please note The diagrams provided in the manual are for guidance only Due to continual product development the diagrams provided on the units themselves should be followed where any discrepancie...

Страница 36: ...s in temperature and does not indicate a problem Insufficient airflow either hot or cold Inappropriate temperature setting Air inlet or outlet of indoor or outdoor unit has been blocked Air filter is...

Страница 37: ...fault EC Outdoor Communication fault EE Outdoor EEPROM fault EF Outdoor fan motor fault DC motor EH Outdoor suction temperature sensor fault En Outdoor gas pipe temperature sensor fault EP Temp switch...

Страница 38: ...tage lower voltage 3 Overcurrent 4 Exhaust over temperature protection 5 Outdoor coil over temperature protection 6 Drive fault and protection V1 VP1 7 Communication fault with indoor unit 8 Compresso...

Страница 39: ...s indicates that the AC has been reset and the mobile device has lost contact with the AC Reconnect the device following the above instructions If this fails delete the AC from your devices list and s...

Страница 40: ...kW 5 20 5 29 5 20 5 29 Balance point temperature heating oC 7 7 Min outdoor operating temperature oC 15 15 Thermostat off mode W 15 15 Standby mode W 2 2 Off mode W 0 0 Annual consumption kW 294 1540...

Страница 41: ...ned by F Gas regulations The gas must be handled by qualified F Gas engineers APPENDIX Disposal Do not dispose this product as unsorted municipal waste Collection of such waste must be handled separat...

Страница 42: ...labour only We recommend that you note the details of your purchase below and retain your original proof of purchase receipt with this manual Keep these documents safe in the event of a warranty clai...