TCL iQool-2MS9K9K Скачать руководство пользователя страница 1

 

 

 

USER AND INSTALLATION MANUAL 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

WHITE 

BLACK 

 

iQool-2MS9K9K 

iQool-2MS9K9KB 

2 x 9,000 BTU Indoor 

iQool-2MS12K12K  iQool-2MS12K12KB 

2 x 12,000 BTU Indoor 

 
 

SMART WIFI CONTROLLED WALL MOUNTED INVERTER  

MULTI SPLIT AIR CONDITIONER WITH HEAT PUMP 

 

Thank you for choosing a TCL Air Conditioner 

Please read this user manual before using this innovative  

Air Conditioner and keep it safe for future reference. 

Содержание iQool-2MS9K9K

Страница 1: ...l 2MS12K12K iQool 2MS12K12KB 2 x 12 000 BTU Indoor SMART WIFI CONTROLLED WALL MOUNTED INVERTER MULTI SPLIT AIR CONDITIONER WITH HEAT PUMP Thank you for choosing a TCL Air Conditioner Please read this...

Страница 2: ...A DEVICE 15 CONNECTING USING CF MODE QUICK CONNECTION 16 CONNECTING USING AP MODE ALTERNATIVE METHOD 17 USING THE TIMER FUNCTION 20 MORE SETTINGS 21 MAINTENANCE 22 END OF SEASON 23 START OF SEASON 23...

Страница 3: ...conditioner contains R32 which is a safe efficient refrigerant which has a lower environmental burden than traditional refrigerants The refrigerant used in this air conditioner is an environmentally f...

Страница 4: ...any variance between the manual and the product received the information provided on the product should be followed ENERGY SAVING AND UNIT SAFETY PROTECTION TIPS Do not cover or restrict the airflow f...

Страница 5: ...ne 5 Liquid line 6 Compressor 7 Condenser 8 Condenser Fan HEAT PUMP MODE The system operates in reverse the condenser works as an evaporator the evaporator as a condenser warm air is blown into the ro...

Страница 6: ...Display 5 Signal receiver 6 Terminal block cover 7 Ionizer generator not applicable on all models 8 Deflectors 9 Emergency button 10 Indoor unit rating label 11 Airflow direction louver No Description...

Страница 7: ...5 Timer Press to set the timer 6 Sleep Press to activate the SLEEP function 7 Eco In cooling mode press to increase the set temperature by 2oC In heating mode press to decrease the set temperature by...

Страница 8: ...ence between the set temperature and the room temperature SETTING UP THE REMOTE When batteries are first inserted into the remote or following changing the batteries the remote must be set up for COOL...

Страница 9: ...e best performance The operation logic is as below Ambient Temperature Operation Mode Auto Temperature 20 C Heating 23 C 20 C 26 C Dry 18 C 26 C Cool 23 C 3 Use the FAN button to set the fan speed TIM...

Страница 10: ...15 minutes before returning to their previously set levels SWING 1 Press the SWING buttons to control the fan direction 2 The controls the horizontal air movement up down 3 The button is not activate...

Страница 11: ...se of the room where the air conditioner is installed Strong sunlight and the presence of people lights or equipment creates an additional heat load Normal living spaces require about 350 Btu per squa...

Страница 12: ...ir conditioner requires a good signal during the setup process Your air conditioner is designed to be connected to a 2 4ghz network and the connection is set up using the TCL SMART LIFE app We would a...

Страница 13: ...ill need to be registered Click on the Register button to enter the registration screen The account can be created by using either the default option of an email address or alternatively by SMS messag...

Страница 14: ...our new password in the box below Please note the password should be at least 6 characters and include letters and numbers Then press the confirm button to log in FORGOTTEN PASSWORD Should the passwor...

Страница 15: ...e device within the app and as such the following connection process should be repeated for each indoor unit CHANGING BETWEEN CONNECTION TYPES To change the unit between the two connection types quick...

Страница 16: ...your Wifi router from the drop down list and enter the password Please note the password is case sensitive before pressing next The app will automatically upload the connection information to the air...

Страница 17: ...isplayed 2 Press on the AP Mode button in the top right of the screen to change the app to AP mode connection 3 Select your Wifi router from the drop down list and enter the password Please note the p...

Страница 18: ...itioner once the connection is completed a message will be displayed to confirm On this page there is the option to rename the air conditioner to something more relevant If the connection fails please...

Страница 19: ...e desired temperature The tabs on the bottom of the screen should be used to change other settings Mode Allows the operating mode to be changed between Feel Heat Dry Cool and Fan Speed Allows the fan...

Страница 20: ...e bottom of the screen If there is a timer already programmed that you would like to amend press and hold the timer which requires amendment OFF TIMER 1 Select Timer Off 2 Set the time the air conditi...

Страница 21: ...the main screen the three dots in the top right hand corner give you access to the settings options for the app This a number of extra options for modifying the name of the air conditioner and removi...

Страница 22: ...ry dirty it may be washed in lukewarm water with a very small amount of neutral detergent Rinse well and allow to dry completely not in direct sunlight or near a source of heat 3 Keep the front panel...

Страница 23: ...lled within the indoor unit and is clean Check that the condensation outlet drains properly and there is no dirt or organic blockage otherwise leakage may occur Install 2 AAA batteries in the remote c...

Страница 24: ...age and frequency This unit is only suitable for an earthed electrical supply connection voltage 230 V 50 Hz The information specifications and parameter are subject to change due to technical modific...

Страница 25: ...utside of direct sunlight or strong winds which is not on a flood line and where noise and airflow does not cause interference or inconvenience Select a location where there are no obstructions to the...

Страница 26: ...26 RECOMMENDED INSTALLATION SPACING DIAGRAM...

Страница 27: ...it Level Number 14 7mm Masonry Drill Pencil and Chalk 1 5 inch number 10 screws Small Stepladder 7mm Wall Plugs Protective Glasses and Mask Pipe and Cable Detector 4 inch Plastic Ties 2 Inch Pipe Clip...

Страница 28: ...rest of the holes and insert the wall plugs 8 Fix the backplate to the wall 9 Mark the hole centre and make sure the cutter will clear the backplate 10 Drill the hole at a slight downwards angle When...

Страница 29: ...Insert the piping hole sleeve into the hole to prevent the connecting piping and wiring from been damaged when passing through the hole The piping can be lead out on the right left or directly behind...

Страница 30: ...unit horizontally Use expansion bolts to fix the mounting supports on the wall Use bolts and nuts to fix the outdoor unit firmly on the supports and keep on the same level If the unit is installed on...

Страница 31: ...outdoor units and the connecting pipe 2 Align the joint of the connecting pipe between the indoor and outdoor and tighten the connecting nut by hand to prevent cross threading Secure them with a wrenc...

Страница 32: ...ank caps of the 2 way and 3 ways valves applying the torque listed in the table above ADDING REFRIGERANT Refrigerant must be added if the pipe length is more than 5 metres 16 5 This operation can only...

Страница 33: ...ake the packed soft pipes vertical before extending Please do not extend only one side of the packed soft pipes Please make use of semicircle pulley to keep the allowed bending angle Extreme bending c...

Страница 34: ...e the unit and invalidate the warranty Secure the wires and replace the cover before operating the unit The appliance should be installed in accordance with national wiring regulations If the supply c...

Страница 35: ...GRAMS Please note The diagrams provided in the manual are for guidance only Due to continual product development the diagrams provided on the units themselves should be followed where any discrepancie...

Страница 36: ...s in temperature and does not indicate a problem Insufficient airflow either hot or cold Inappropriate temperature setting Air inlet or outlet of indoor or outdoor unit has been blocked Air filter is...

Страница 37: ...fault EC Outdoor Communication fault EE Outdoor EEPROM fault EF Outdoor fan motor fault DC motor EH Outdoor suction temperature sensor fault En Outdoor gas pipe temperature sensor fault EP Temp switch...

Страница 38: ...tage lower voltage 3 Overcurrent 4 Exhaust over temperature protection 5 Outdoor coil over temperature protection 6 Drive fault and protection V1 VP1 7 Communication fault with indoor unit 8 Compresso...

Страница 39: ...s indicates that the AC has been reset and the mobile device has lost contact with the AC Reconnect the device following the above instructions If this fails delete the AC from your devices list and s...

Страница 40: ...kW 5 20 5 29 5 20 5 29 Balance point temperature heating oC 7 7 Min outdoor operating temperature oC 15 15 Thermostat off mode W 15 15 Standby mode W 2 2 Off mode W 0 0 Annual consumption kW 294 1540...

Страница 41: ...ned by F Gas regulations The gas must be handled by qualified F Gas engineers APPENDIX Disposal Do not dispose this product as unsorted municipal waste Collection of such waste must be handled separat...

Страница 42: ...labour only We recommend that you note the details of your purchase below and retain your original proof of purchase receipt with this manual Keep these documents safe in the event of a warranty clai...