L2E Repair Document
TCL
Communication Ltd.
Rev.
9015B
Level 2E Repair Document
Page
1.0
15/41
All rights reserved. Transfer, copy, use or communication of this file is prohibited without authorization.
5.4 Disassembly Notice:
1). Receiver is easily to be damaged during disassembly process. Thus please do not
disassemble receiver unless it is necessary.
2). About battery disassemble notice:
The battery can’t be reused when you disassemble it.
Improper operation on battery will cause high risk for fire or burning. Thus please follow
up the battery disassembly guidance strictly and pay high attention to the WARNING
part. Do not disassemble battery unless it is necessary.
3). Put all the spare parts on right position (don’t let all the spare parts mixed and put on the
clean place to avoid vitiated or stained for each spare part) after disassembly.
5.5 Reassembly process
Please make reference to the disassembly process for assembly reverse an order of the disassembly
steps.
Attention:
When assembling Furnished frame, make sure the TP FPC and LCD FPC connected firstly.
Before assembling furnished back cover, please check whether there’s any deformation or damage
for the buckles; if yes, replace it with a new furnished back cover.