TCL AC12000E Скачать руководство пользователя страница 12

Page 

12

 of 

18

 

 

SLEEP BUTTON 

This function is useful for night as it gradually reduces the operation of the air conditioner 
when running in cooling mode.    The air conditioner will run with a low fan speed and the 
desired temperature will increase by 1°C per hour for two hours ( i.e max of 2°C above 
temperature originally set).    The unit will then continue to run set at this temperature for a 
further 6 hours before entering standby mode. 
 
To operate the sleep mode press the

button and a

 

  will be displayed under the icon 

on the display. 
 
The sleep mode can be cancelled at any time using the Sleep

, Mode 

, or Fan Speed 

buttons. 

 

INSERTING OR REPLACING THE BATTERIES 

  Remove the cover on the rear of the remote 

control. 

 

Insert two “AAA” 1.5V batteries ensuring they are in 
the correct position. 

  Replace the battery cover. 

 

MULTI PROTECTIVE FUNCTIONS

 

 

ANTI-FREEZE PROTECTION   

When  the  ambient  temperature  is  low  while  in  Cooling  Mode,  the 

compressor  and  water  motor  will  stop  working  if  the  copper  coil 

temperature  reaches  <2

  for  over  20  seconds.  When  the  copper  coil 

temperature increases to >8

, the protection will be stopped automatically. 

During this operation “Lt” will be displayed on the unit. 

 

WATER-FULL PROTECTION 

When the water level in the internal water tank is surpassing the maximum 

level, the unit will alert automat

ically and “Ft” will show on the LED screen. 

Please discharge water from the machine according to 

“Water Drainage” 

instructions 

 

COMPRESSOR DELAY-PROTECTION   

The  compressor  runs  under  a  3  minute  delay  protection  function  and  so  it  can  take  3 

minutes  after  cooling  or  dehumidifying  mode  has  been  selected  before  the  compressor 

starts to run. 

 

COMPRESSOR PROTECTION 

In  cooling  and  dehumidifying  modes  if  the  temperature  difference  between  the  coil 

temperature and room temperature is less than 3

, for more than 30 minutes, the machine 

will  enter 

‘no  refrigerant’  compressor  protection  mode.  The  compressor  and  water  pump 

motor will stop working. Normal operation will resume in due time. 

Содержание AC12000E

Страница 1: ...NUAL AC12000E 12 000 BTU PORTABLE AIR CONDITIONER With WIFI Smart App Thank you for choosing TCL Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference ...

Страница 2: ...NTS SAFETY INSTRUCTIONS 3 FEATURES 4 PARTS LIST 5 ACCESSORIES 5 INSTALLATION 6 VENTING 7 OPERATION AND SETTINGS 8 CONNECTING THE AIR CONDITIONER TO WIFI 13 WATER DRAINAGE 14 MAINTENANCE 15 TROUBLESHOOTING 16 APPENDIX 17 ...

Страница 3: ... this appliance Do not clean the unit by spraying it or immersing it in water Never connect the unit to an electrical outlet using an extension cord If an outlet is not available one should be installed by a qualified electrician Never operate this appliance if the cord or plug is damaged Ensure the power cord is not stretched or exposed to sharp objects edges A damaged supply cord should be repla...

Страница 4: ... to low and set the thermostat to your desired setting To protect the unit we recommend not using the cooling function when the ambient temperature is higher than 35 C FEATURES Take control of your air conditioner from anywhere at any time using your smartphone Simply connect the dehumidifier to your WIFI network and download the app onto your android or ios smartphone The louvres close automatica...

Страница 5: ...Page 5 of 18 PARTS LIST ACCESSORIES ...

Страница 6: ... on the Air outlet grille and twist anticlockwise to lock it into place INSTALLATION OF WINDOW KIT Partially open a window and then fix the window slider kit to the window as shown in the diagrams below This method works with most standard sash or vertical sliding windows The window kit is not designed to be used with other styles of window although the kit may be adapted for use with other window...

Страница 7: ...operation and unrestricted airflow Do not use in laundry rooms or areas where relative humidity is higher than 80 The unit should be placed on a firm level surface to minimise noise and vibration Carpeted surfaces help reduce noise caused from the vibration of the unit during operation VENTING THE AIR CONDITIONER Please make sure the vent hose is not kinked or bent The operation of the unit will b...

Страница 8: ... mode The control panel on the top of the appliance enables basic control of the air conditioner For access to all the features the remote should be used CONTROL PANEL CONTROL PANEL FUNCTIONS ON OFF BUTTON Press this button to turn the unit on and enter the last function that was running before the unit was turned off Press again and the unit will switch off MODE BUTTON Press this button to choose...

Страница 9: ...lease note only one timer can be used at any time Below 10 hours this can be set in 30 minute increments and between 10 and 24 hours in 1 hour increments ON TIMER The timer will turn on the unit automatically after the time set has elapsed The unit will start with the same settings as when the unit was put into standby 1 When in standby press the button then set the number of hours time you desire...

Страница 10: ...ecrease the time set in the timer MODE SELECTION BUTTON Press this button to cycle through the operational modes of the air conditioner The mode chosen will be shown by an arrow on the left hand side of the screen on the remote The remote has auto mode in addition to the options found on the air conditioner which will aim for a temperature of 23 C above this temperature the unit will operate in co...

Страница 11: ... timer will turn off the unit automatically after the time set has elapsed 1 While the unit is operating press the button the display will show a at the bottom next to OFF 2 Set how long you require the unit to run by pressing the and buttons 3 Once the set time has elapsed the unit will turn off automatically 4 If the button is pressed before the time has elapsed the timer will be cancelled and t...

Страница 12: ... low while in Cooling Mode the compressor and water motor will stop working if the copper coil temperature reaches 2 for over 20 seconds When the copper coil temperature increases to 8 the protection will be stopped automatically During this operation Lt will be displayed on the unit WATER FULL PROTECTION When the water level in the internal water tank is surpassing the maximum level the unit will...

Страница 13: ... is set up using the TCL SMART LIFE app We would advise on using the QR codes below to ensure the correct app is downloaded Android IOS You can use the unit together with other Tuya smart devices by using the Smart Life app by TUYA which is also available on the app store although some features may be limited so would advise on using the version above which is optimised for use with your air condi...

Страница 14: ...rain hose can be higher than the drain outlet otherwise the tank will not drain Notes This model has a self evaporative function which reduces the need to empty the water tank Please ensure the rubber bung is in position if using the self evaporation function If the unit is vented correctly in cooling mode most of the water is reused to cool the condenser coil and any excess is evaporated If using...

Страница 15: ...rsing it in warm about 40 water with a neutral detergent d Rinse it and then dry it thoroughly e Carefully re install air filter END OF SEASON MAINTENANCE 1 Pull out the plug from the bottom drainage hole and empty the internal tank You can also drain the water by leaning the unit 2 Switch the unit to Fan mode and select low fan speed 3 Keep the unit in this mode for 6 12 hours until the conduit i...

Страница 16: ...surface Carpet under the unit can prevent vibrations Compressor does not work Overheating protection is active Check venting Restart the unit after 5 minutes when the compressor has cooled Remote control doesn t work Operating distance is too far Move the remote control closer to the unit and make sure it is aimed at the air outlet grille Control panel has not received the signal from remote contr...

Страница 17: ...ontact the local council for details of your local household waste recycling centres TECHNICAL DATA Capacity 3 35 kWh 12 000 BTU Rated Current 5 5 A Rated Input 1 28 kW Maximum input power 1 4 kW Maximum input current 6 7 A Air Flow 330 m3 h Noise 54dB A EER 2 6 Max Noise Level Sound Pressure 65 db Max Noise Level Sound Energy 54 db Energy Rating Cooling Heating A Maximum Suction Pressure 2 1 MPa ...

Страница 18: ...e online form 1 Has the unit been standing upright for at least 2 hours 2 Is the unit plugged into the mains 3 Is the fuse OK 4 Switch the unit off and wait three minutes to see if the issue is resolved Restart the unit 5 Check if the water tank is full Office hours 9AM 5PM Monday to Friday TCL AIR CONDITIONING Unit J6 Lowfields Business Park Lowfields Way Elland West Yorkshire HX5 9DA ...

Отзывы: