第
3
页共
11
页
2. General introduction
FACTORY MENU
ITEMS
Default
Setting
Description
St
at
us
1-Factory hotkey
Off
Factory hotkey Switch (OFF/ON).Should be OFF
after factory alignment
OK
2-WARM-UP
Off
OFF:The set would enter standby mode after
15 minutes without input signal;
ON:Aging mode. Aging time will display on
the left bottom of screen.
NOTE: Enter and exit the aging mode method: 1,
press on the remote control Left and right the cursor
keys will Factory hotkey set to ON; 2, WARM UP is set
to ON; according to the panel on the "menu" button to
exit the aging mode
OK
3-ADC
ADC calibration(refer as follow)
,NOTE: Not
adjust
OK
4-White balance
White Balance data adjustment ( refer as
follow)
The balance data is set by PE before the mass
production. Do not need adjust.
OK
5-SHOP
init(Option)
DO
Reset
the
set
after
production
alignment;(This operation will remove all
unnecessary factory value; The factory
hotkey will be turn off)
OK
6-NVM reset
DO
System initialization. Restore all data
except the White Balance and ADC data ;Only
for R&D.
OK
7-Preset Factory
Channel
DO/HZ
Preset specific factory channels for
specific factory. Press left and right
button to select the factory, and then press
OK to confirm.
OK
8-Power on mode
LAST
On: Always turns on TV when AC power on
STB:Always goes to standby mode when AC power
on
LAST:Restore the status before the last AC
power off
OK
Содержание 40D2930
Страница 37: ......