![TCL 39D30 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/tcl/39d30/39d30_service-manual_824950013.webp)
第
7
页共
11
页
DATE
Date and time of software releasing
OK
Project Name
Module name
OK
SIACP
VERSION
SIACP VERSION
OK
Chassis
MS82
Chassis name
OK
PANEL
P/N of panel
OK
NG
PROJECT ID
Project Select submenu
OK
PWON_MUSIC
ON
Power on music
USB UPDATE
USB UPDATE
ok
HOTEL ENABLE OFF
HOTEL MENU SWITCH
ok
ERROR CODE
OFF
Error prompt
OK
POWER_LOGO
TCL/HYUDNA
I
Select the logo of customer
0K
LOGO_LIGHT
ON
LOGO LIGHT SWITCH
OK
TCL_SHOW
ON
TCL SHOW SWITCH
OK
5. Debugging
5.1. General Steps of debugging
According to the requirement of the order, below steps are needed for
appropriate setting.
1)
Enter the Factory Menu, enable FAC HOTKEY.
2)
Check Project ID and the version of software, release date displayed
at the bottom of Factory Menu.
3)
Enter Design Menu, choose SERVICE MENU->Project ID, choose
corresponding Project ID number of the product (Refer to the
“V6-PROJECT -ID0**”in the BOM list).
4)
Return to Factory Menu, check the Product model.
5)
Choose Factory Menu->NVM RESET and press the right button of the
remote and wait until prompt OK appears.
6)
Restart the set
7)
According to the requirement of the order, Set the items of SHOP
INIT and Hotel Menu etc.
8)
After aging under normal temperature, calibrate ADC and adjust
white balance.
9)
Choose Factory Menu ->SHOP and press the button of remote to
initialize the set.