TCi HarmonicGuard HSP Скачать руководство пользователя страница 1

 

HSP 

Single – Phase Harmonic Filter 

HarmonicGuard

®

 Series Drive-Applied Harmonic Filter 

Installation, Operation, and Maintenance Manual 

 
 

TCI, LLC 

W132 N10611 Grant Drive 

Germantown, Wisconsin 53022

 

Phone: 414-357-4480 

Fax: 414-357-4484 

Helpline: 800-TCI-8282 
Web Site: http://www.transcoil.com 

© 

2017 

Revision A 

 

 
 
 
 

Содержание HarmonicGuard HSP

Страница 1: ...Series Drive Applied Harmonic Filter Installation Operation and Maintenance Manual TCI LLC W132 N10611 Grant Drive Germantown Wisconsin 53022 Phone 414 357 4480 Fax 414 357 4484 Helpline 800 TCI 8282...

Страница 2: ...otherwise without the prior written permission of TCI LLC The information in this manual is subject to change without notice Every precaution has been taken in the preparation of this manual TCI LLC a...

Страница 3: ...Revision Description Date 1 0 Release 6 16 11 A Removed No contactor option minor edits and corrections 8 21 17...

Страница 4: ......

Страница 5: ...ving Inspection and Storage 3 Pre installation Planning 4 Installation Guidelines 5 HSP Harmonic Filter Operation 7 Installation 8 Maintenance and Service 9 Product Description 11 Drawings 13 Standard...

Страница 6: ......

Страница 7: ...taken to avoid conditions which can lead to a serious fault condition physical injury or death Cautions are used to call attention to instructions that describe steps that must be taken to avoid condi...

Страница 8: ...dance with the National Electrical Code NEC and or any other codes that apply to the installation site Warning Disconnect all power before working on the equipment Do not attempt any work on a powered...

Страница 9: ...his warranty shall not apply if the product was a Altered or repaired by anyone other than TCI b Applied or used for situations other than those originally specified or c Subjected to negligence accid...

Страница 10: ...and dust Excessive vibration Working Space Provide sufficient access and working space around the unit to permit ready and safe installation operation and maintenance Make sure that the installation c...

Страница 11: ...d tightening torque for the grounding and power terminals are listed in Table 1 Refer also to the drawings and other information shipped with the unit Table 1 Power Terminal Wire Size Capacity Range a...

Страница 12: ...the requirements of the National Electrical Code and or other applicable electrical codes For units rated less than 100 amps use wire with an insulation temperature rating of 60 C or higher For units...

Страница 13: ...re applying power and operating the equipment for the first time Before Applying Power for the First Time Inspect the installation to make sure that all equipment has been completely and correctly ins...

Страница 14: ...y purpose requiring exact data Contact the factory in situations where certified data is required All data is subject to change without notice Installation Checklist The following are the key points t...

Страница 15: ...s often as necessary to prevent dirt build up from impeding air flow Check the operation of the cooling fan Inspect the interior of the enclosure for signs of overheated components Clean the interior...

Страница 16: ...80 75 100 100 150 contact factory for additional information Table 3 Fuse Specifications for HSP 240 Volt Models HSP Rating Power Circuit Fuse Ratings HP Amps Type 5 20 7 5 25 10 30 15 40 20 50 25 70...

Страница 17: ...in an enclosure with the drive or other equipment The HSP filters consist of the following features and components A KDS input series reactor to prevent system interaction and improve filter performan...

Страница 18: ...designed for use with a 25 Hp drive Figure 1 HSP Part Number Encoding Product Technical Specifications Table 3 lists the major technical specifications for the HSP single phase Harmonic Filter Table...

Страница 19: ...ngs shipped with the unit Be sure to carefully review the information on the provided drawings The information on the drawings provided with the filter takes precedence over the information provided i...

Страница 20: ...rmonicGuard HSP Drawings 14 HSP IOM Manual Rev A Typical Outline Drawing Figure 2 Typical HSP Outline Drawing This drawing is not representative of all units specific drawings are shipped with product...

Страница 21: ...HarmonicGuard HSP HSP IOM Manual Rev A 15 Typical Schematic 1 Figure 3 HSP Schematic with Fan and Flipper Open This schematic is not representative of all units specific schematics are shipped with p...

Страница 22: ...uard HSP Drawings 16 HSP IOM Manual Rev A Typical Schematic 2 Figure 4 HSP Schematic with Fan and Flipper Closed This schematic is not representative of all units specific schematics are shipped with...

Страница 23: ...ingle phase harmonic filter is a passive filter connected in series with the input terminals of a variable frequency drive or several drives that operate as a group It is designed to provide a low imp...

Страница 24: ...tional information Product Description HSP CP Option Single Phase Harmonic Filter The HSP CP Option filter components is a package of the primary passive filter components needed to build a harmonic f...

Страница 25: ......

Страница 26: ......

Страница 27: ...10611 Grant Drive Germantown Wisconsin 53022 Phone 414 357 4480 Fax 414 357 4484 Helpline 800 TCI 8282 Web Site http www transcoil com 2016 TCI LLC Publication No 27715 Effective 08 25 16 Revision A P...

Отзывы: