Impeller Placement
HIB, RTF Impeller Overlap
Size
A
B
Size
A
B
180
20.50 0.31
400
45.25 0.69
200
22.50 0.34
450
50.00 0.75
220
25.00 0.38
490
55.13 0.81
240
27.50 0.44
540
61.00 0.91
270
30.38 0.47
600
67.50 1.00
300
33.50 0.50
660
74.25 1.13
330
37.00 0.56
730
82.00 1.22
360
41.00 0.63
800
90.75 1.34
HRT Impeller Overlap
Size
A
B
(Design 19)
B
(Design 23)
270
27.00
0.50
0.50
300
30.00
0.69
0.69
330
33.00
0.69
0.69
360
36.50
0.81
0.81
400
40.25
1.03
0.97
450
44.50
1.13
1.06
490
49.00
1.25
1.13
540
54.25
1.38
1.25
600
60.00
1.31
1.31
660
66.00
1.56
1.44
730
73.00
1.75
1.63
800
80.75
1.06
1.31
HAF Impeller Overlap
Size
A
B
220
25.00
0.50
240
27.50
0.55
270
30.38
0.61
300
33.50
0.67
330
37.00
0.74
360
41.00
0.75
400
45.25
0.83
450
50.00
0.91
490
55.13
1.01
540
61.00
1.12
600
67.50
1.23
660
74.25
1.36
730
82.00
1.50
800
90.75
1.66
Models BC-SW, BAF-SW, BAE-SW, BCS, HIB,
BAV, RTF, HRT, HAF, BCV, DCV, TCBI
BCV (Class L)
Impeller Overlap
Size
B
090-105
0.28
122
0.31
135
0.34
150
0.38
165
0.44
182
0.56
200
0.63
222
0.69
245
0.75
270
0.88
300
0.97
330
1.06
365
1.31
BC-SW, BC-DW, BAF SWSI & DWDI, BCS, BCV (Class I & II), DCV Impeller Overlap
Size
105
122
135
150
165
182
200
222
245
270
300
330
365
402
445
490
542
600
660
730
807
890
A
10.50 12.25 13.50 15.00 16.50 18.25 20.00 22.25 24.50 27.00 30.00 33.00 36.50 40.25 44.50 49.00 54.25 60.00 66.00 73.00 80.75 89.00
B
0.28 0.31 0.34 0.38 0.38 0.47 0.52 0.55 0.59 0.67 0.75 0.82 0.72 0.90 1.00 1.10 1.25 1.24 1.36 1.88 2.09 2.28
BAV, BAE-SW & BAE-DW Impeller Overlap
Size
122
135
150
165
182
200
222
245
270
300
330
365
402
445
490
542
600
660
730
807
890
982
A
12.25 13.50 15.00 16.50 19.00 20.82 23.16 25.51 28.11 31.23 34.36 38.00 41.90 46.33 51.01 56.48 62.47 68.71 73.00 80.75 89.00 98.25
B
0.31 0.34 0.38 0.44 0.38 0.41 0.45 0.50 0.55 0.61 0.67 0.75 0.82 0.91 1.00 1.11 1.23 1.35 1.50 1.65 1.82 2.02
Note: On swingout fans, the impeller and funnel should be positioned as close as possible (max gap 1/8”) such that the door can be opened without
the impeller and funnel interfering.
Models BC-DW, BAF-DW, BAE-DW
TCBI (60 Hz)
Impeller Overlap
Size
B
3
0.34
5
0.38
7.5
0.38
10
0.38
15
0.31
20
0.31
25
0.31
30
0.31
TCBI (50 Hz)
Impeller Overlap
Size
B
3-50
0.56
5-50
0.56
7.5-50
0.56
10-50
0.56
15-50
0.56
20-50
0.63
25-50
0.63
30-50
0.63
Twin City Fan