TCE Group SRL
|
VIA G. DI VITTORIO - 35046 BORGO VENETO (PADOVA)
–
ITALIA
WWW.TCECHARGERS.COM
Lead Acid charging curve
–
Heavy Duty
Curva di carica Piombo Acido
–
Trazione pesante
S1:
The current rises from I1=2a to I2=10A in
“
soft start
”
mode.
S2:
The current remains constant at 10A until reaching the
U1 = 2.45 V/cell threshold or reaches the maximum
allowed time for this phase of 8h.
S3:
Upon reaching 2.45 V/cell the current remains constant
I3=8A until U2=2.55 V/cell is reached or reaches the
maximum allowed time for this phase of 2.5h.
S4:
The voltage remains constant U2=2.55 V/cell, the
current drops to I4=4A or reaches the maximum allowed
time for this phase of 3h.
S5:
The current I4=4A remains constant until the final
voltage U3=2.68 V/cell is reached or the maximum allowed
time for this phase of 4h is over.
Charging information
Maximum charging time: 14 hours
Max V/Cell: 2.68 V/cell
Floating: 2.55 V/cell
S1:
La corrente cresce da I1=2A fino a I2=
10A in modalità “sof
t
start”
.
S2:
La corrente rimane costante a 10A fino al raggiungimento
di U1=2.45 V/cella o raggiunge il tempo massimo concesso per
questa fase di 8 ore.
S3:
Al raggiungimento dei 2.45 V/cella, la corrente rimane
costante I3=8A fino a raggiungere la soglia di U2=2.55 V/cella
o raggiunge il tempo massimo concesso per questa fase di 2,5
ore.
S4:
La tensione rimane costante U2=2.55 V/cella, la corrente
scende fino a I4=4A o raggiunge il tempo massimo concesso
per questa fase di 3 ore.
S5:
La corrente I4=4A rimane costante fino al raggiungimento
della tensione U3=2.68 V/cella o raggiunge il tempo massimo
concesso per questa fase di 4 ore.
Informazioni di carica
Tempo di carica massimo: 14 ore
Max V/Cella: 2.68 V/cella
Floating: 2.55 V/cella