11. setting the lancing frequency
Caution!
Risk of injury due to excessive piercing frequency. If the piercing frequency is too
high, the skin is cut open. Make sure that the piercing depth, skin texture and needle projec-
tion are adapted to the working speed. Always start with the lowest level!
1. Switch on the MAGERO®.
2. Press + and - to set the piercing frequency/speed in eight preset steps (with the ma-
chine running or at a standstill).
12. handle piece
The handle piece can be changed if necessary or removed for cleaning.
1. Switch off the MAGERO®.
2. Use the allen key to loosen the worm screw on the underside of the handle.
3. Unscrew the handle.
4. Change/clean the handle.
5. Screw the handle back onto the machine as far as it will go.
6. Fix the handle piece hand-tight with the worm screw and the allen key.
13. protective covers
Attention!
If liquids get inside the MAGERO® , this can cause damage to mechanical and
electronic components. A contaminated machine can lead to cross-contamination. Therefo-
re, always use protective sleeves!
•
Make sure that the machine, handle and drive ram are clean.
•
Use an approved protective hose and pull it properly over the machine and fix it as
usual. Make sure that there is no gap after attaching the cartridge so that the machine
cannot be contaminated.
•
If liquids get inside the MAGERO®, it can cause malfunctions. Remove the battery and
return the MAGERO® to the manufacturer, preferably in its original packaging. Do not
use again!
Содержание BLACKGOLD MAGERO