11. setting the lancing frequency 

Caution! 

Risk of injury due to excessive piercing frequency. If the piercing frequency is too 

high, the skin is cut open. Make sure that the piercing depth, skin texture and needle projec-

tion are adapted to the working speed. Always start with the lowest level!

1.  Switch on the MAGERO®. 

2.  Press + and - to set the piercing frequency/speed in eight preset steps (with the ma-

chine running or at a standstill). 

12. handle piece

The handle piece can be changed if necessary or removed for cleaning. 

1.  Switch off the MAGERO®.

2.  Use the allen key to loosen the worm screw on the underside of the handle.

3.  Unscrew the handle. 

4.  Change/clean the handle.

5.  Screw the handle back onto the machine as far as it will go. 

6.  Fix the handle piece hand-tight with the worm screw and the allen key. 

13. protective covers

Attention! 

If liquids get inside the MAGERO® , this can cause damage to mechanical and 

electronic components. A contaminated machine can lead to cross-contamination. Therefo-

re, always use protective sleeves!

• 

Make sure that the machine, handle and drive ram are clean.

• 

Use an approved protective hose and pull it properly over the machine and fix it as 

usual. Make sure that there is no gap after attaching the cartridge so that the machine 

cannot be contaminated.  

• 

If liquids get inside the MAGERO®, it can cause malfunctions. Remove the battery and 

return the MAGERO® to the manufacturer, preferably in its original packaging. Do not 

use again! 

Содержание BLACKGOLD MAGERO

Страница 1: ...INSTRUCTION MANUAL Read carefully before operation BLACKGOLD MAGERO brands of TCA Systems GmbH Huttengasse 27 1 25 1160 Vienna...

Страница 2: ...t support blackgold tattoo We wish you a lot of fun and success with your new equipment Best regards from Vienna your BLACKGOLD team 1 table of contents 1 Table of contents 2 Warranty statement 3 Safe...

Страница 3: ...requency of pricks is too high injuries cuts in the skin may occur If hygiene rules are not observed infections may occur leading to illness If used for too long unacceptable heating may occur due to...

Страница 4: ...4 0 7 operating conditions Ambient temperature 10 to 30 C Relative humidity 30 to 75 4 scope of delivery 1 BLACKGOLD MAGERO tattoo machine 2 battery cells 18500 Li NMC 3 7V 2000mAh CID PCT 1 Dual Char...

Страница 5: ...AGERO If there are signs of a malfunction the rechargeable battery must be removed immedia tely and must never be left unattended in the device If defective or other battery cells are used the followi...

Страница 6: ...ock mechanism adjust the needle projection by loosening the handle by turning it clockwise by about 10 3 Now set the desired needle projection by carefully moving the handle forward backward 4 Fix the...

Страница 7: ...w the handle 4 Change clean the handle 5 Screw the handle back onto the machine as far as it will go 6 Fix the handle piece hand tight with the worm screw and the allen key 13 protective covers Attent...

Страница 8: ...unterclockwise and pull it out of the MAGERO Pick up color Dip the tip of the module into the desired color for 2 3 seconds while the unit is run ning Make sure that the sensitive needle tip does not...

Страница 9: ...gnation of the machine Tattoo machine Type MAGERO Year of construction 2021 Consisting of Neodymium magnets aluminum plastic housing drive unit Relevant EC Directives EC Machinery Directive 2006 42 EC...

Страница 10: ......

Отзывы:

Похожие инструкции для BLACKGOLD MAGERO