______________________________________________________________________________________________________________________________________________________________________________
____________________
TC Electronic A/S
M5000 Service manual
page 15
Replacing battery:
Recommended battery type: CR2032.
TC stock no. (TCcode) for battery: 342 0000 11
Replace procedure:
1.
Turn Off Power and Disconnect Power Cord.
2.
Remove top and bottom cover.
3.
Locate the battery on the CPU board.
3.
Desolder the old battery by warming up each terminal one by one. Avoid any
short circuit of the terminals. Be careful not to damage the wiring on the board.
4.
Insert new battery and solder the terminals one by one. Avoid any short circuit of the
terminals.
5.
The voltage measured directly across the terminals of the new battery should be
higher than 3.0VDC.
6.
Do not discard the old battery. Hand it over to a recycling company or your dealer.
Replacing Power Supply Module
Please refer to service note no. 712 10 05 14 in Appendix for replacing power supply module in Mainframe type M5000F20 (serial no. higher than 281447),
Please refer to Appendix I (Power Supply Upgrade) for replacing power supply in mainframe type M5000F10.
CAUTION:
DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED.
REPLACE ONLY WITH SAME OR EQUIVALENT TYPE RECOMMENDED
BY THE MANUFACTURER. DISCARD USED BATTERIES ACCORDING TO
THE MANUFACTURERS INSTRUCTIONS.
VARNING:
Felaktigt batteribyte kan medfora fara for explosion. Anvand darfor endast samma typ
eller likvardig typ enligt apparattillverkarens rekommendation.
Kassera forbrukade batterier enligt tillverkarens anvisning
ADVARSEL:
Lithiumbatteri. Eksplosionsfare ved fejlagtig håndtering. Må kun udskiftes med batteri
af samme fabrikat og type.
Lever det brugte batteri tilbage til leverandøren.