TC Electronic Digital Konnekt x32 Скачать руководство пользователя страница 22

SETUP EXAMPLES

20

Example 2: Conventional audio interface

PREAMP #2

PREAMP #1

CD/DVD PLAYER

COMPUTER

AIR SPEAKERS

FORMAT CONVERTER | PATCHBAY | FIREWIRE IO

digital

konnekt x32

3-4

3-4

3-4

1-2

1-2

1-2

5-6

5-6

5-6

7-8

7-8

7-8

adat

adat

adat

mon

mon

mon

setup

/util

scenes

aes/spdif/tos

in

adat

in

firewire

in

master

clock

aes+spdif+tos

aes+spdif+tos

aes+spdif+tos

SRC

SPDIF

TOS

NS

1-8

44.1k

clock rate

aes

/spdif

monitor LEDs

dual wire XLR

hold to select input

security

lock device

adat

monitor

+phones

WCK

in

fire

wire

INT

48k

x2

x4

TOS IN 5/6

FRONT

aes/spdif clock master

DS

9-16

LOCK

SIG

LOCK

SIG

LOCK

SIG

SEL

1/2

1/2

1/2

3/4

3/4

3/4

5/6

5/6

5/6

7/8

7/8

7/8

SRC

HOLD TO STORE SCENE

input signal

HOLD TO UN-LOCK

192kHz

fs

AES

pro out

1

2

3

4

1-2

1-2

1-2

3-4

3-4

3-4

5-6

5-6

5-6

7-8

7-8

7-8

adat

1-8

adat

1-8

adat

1-8

P

KEYBOARD

TOSLINK
3/4

SPDIF
5/6

SPDIF
7/8

FIREWIRE

AES 1/2

CAT 5

SPDIF
1/2

In this example we show how to use the Digital Konnekt
x32 as a conventional audio interface with four different
external digital sources are connected. For monitoring we
have connected a couple of active monitors equipped
with AES/EBU input.

Connections

A keyboard or another digital instrument with SPDIF
out is connected to SPDIF 1/2 inputs on Digital
Konnekt x32 using a coax cable.

A CD player with Toslink output is connected to TOS
3/4 inputs on Digital Konnekt x32 using a lightpipe
cable.

Two preamps with SPDIF outputs are connected to
the SPDIF inputs 5/6 and 7/8 on Digital Konnekt x32
using coax cable.

Digital Konnekt x32 is connected to the computer via

firewire.

The master Air monitor is fed from Digital Konnekt
x32’s AES 1/2 outputs. The Air slave monitor is
connected to the Air master monitor via a standard
CAT-5 cable.

Содержание Digital Konnekt x32

Страница 1: ...User s Manual EnglishVersion Digital Konnekt x32...

Страница 2: ......

Страница 3: ...ipment should be installed near the socket outlet and disconnection of the device should be easily accessible To completely disconnect from AC mains disconnect the power supply cord from the AC recept...

Страница 4: ...ent from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help For Customers in Canada This Class B digital apparatus complies with Canadian ICES 00...

Страница 5: ...ADAT routing 8 Firewire in 9 Firewire routing 9 Master Clock section 10 Setup Util 11 Scenes 12 Monitor 12 Rear Panel View 13 The integrator 14 SETUP EXAMPLES Example 1 Integrating external hardware...

Страница 6: ......

Страница 7: ...ignal handling Never before have these essential functions been incorporated in a single platform linking your entire fleet of digital devices to your DAW Make your favorite hardware the heart of your...

Страница 8: ...STORE SCENE input signal HOLD TO UN LOCK 192kHz fs AES pro out 1 2 3 4 1 2 1 2 1 2 3 4 3 4 3 4 5 6 5 6 5 6 7 8 7 8 7 8 adat 1 8 adat 1 8 adat 1 8 P FORMAT CONVERTER PATCHBAY FIREWIRE IO digitalkonnekt...

Страница 9: ...he ADAT section any selected sample rate conversion in the AES SPDIF TOS section is deselected AES SPDIF TOS Routing This is the routing section for the AES SPDIF and Toslink inputs Each input channel...

Страница 10: ...clock rate aes spdif monitor LEDs dual wire XLR hold to select input security lock device adat monitor phones WCK in firewire INT 48k x2 x4 TOS IN 5 6 FRONT aes spdif clock master DS 9 16 LOCK SIG LOC...

Страница 11: ...rewire channels 1 8 can be routed to AES SPDIF TOS outputs or to ADAT out Firewire channels 9 16 can be routed to AES SPDIF TOS outputs or to ADAT out Note that ADAT channels are handled in groups of...

Страница 12: ...or LEDs dual wire XLR hold to select input security lock device adat WCK in firewire INT 48k x2 x4 SEL HO input signal HOLD TO UN LOCK 192kHz fs AES pro out 1 2 3 4 5 6 7 8 adat 1 8 P Master Clock In...

Страница 13: ...monitor phones WCK in firewire INT 48k x2 x4 TOS IN 5 6 FRONT aes spdif clock master DS 9 16 LOCK SIG LOCK SIG LOCK SIG SEL 1 2 1 2 1 2 3 4 3 4 3 4 5 6 5 6 5 6 7 8 7 8 7 8 SRC HOLD TO STORE SCENE inpu...

Страница 14: ...4 3 4 5 6 5 6 5 6 7 8 7 8 7 8 SRC HOLD TO STORE SCENE input signal HOLD TO UN LOCK 192kHz fs AES pro out 1 2 3 4 1 2 1 2 1 2 3 4 3 4 3 4 5 6 5 6 5 6 7 8 7 8 7 8 adat 1 8 adat 1 8 adat 1 8 P scenes s R...

Страница 15: ...8 12345687 9872 OUT IN PROFESSIONAL AUDIO EQUIPMENT 100 240V AC 50 60Hz 15W THIS CLASS B DIGITAL DEVICE MEETS ALL REQUIREMENTS OF THE CANADIAN INTERFERENCE CAUSING EQUIPMENT REGULATIONS AND COMPLIES...

Страница 16: ...DAW environment seamless It offers a plug in audio routing representation of your external digital effects processors and operates as a normal VST AU plug in The Integrator plug in can be inserted on...

Страница 17: ...channel by default These are identified by the name of the first channel In the illustration on the previous page channel pair 9 10 is selected even though the label says fw ch 9 When inserting Integr...

Страница 18: ...Integrator plug in allow integration of external digital effect devices with your DAW via Firewire Connections Reverb 4000 is connected via SPDIF coax 1 2 on Digital Konnekt x32 Finalizer 96K is conne...

Страница 19: ...n aes spdif tos SRC SPDIF TOS FRONT aes spdif clock master LOCK SIG 1 2 3 4 5 6 7 8 Clock In the DAW you select External as clock source This allows you to use the Digital Konnekt x32 as master clock...

Страница 20: ...in The Integrator plug in now opens For each external effects unit you want to integrate you make the same considerations as you are used to when setting up software plug in effects insert effects ar...

Страница 21: ...firewire channel 7 8 by selecting fw ch 7 Finalizer 96K The Finalizer will typically be used for mastering Insert Integrator on you master stereo bus Select firewire channel 9 10 by selecting fw ch 9...

Страница 22: ...5 6 5 6 7 8 7 8 7 8 adat 1 8 adat 1 8 adat 1 8 P KEYBOARD TOSLINK 3 4 SPDIF 5 6 SPDIF 7 8 FIREWIRE AES 1 2 CAT 5 SPDIF 1 2 In this example we show how to use the Digital Konnekt x32 as a conventional...

Страница 23: ...te is set on your DAW master clock 44 1k clock rate aes spdif hold to select input adat WCK in firewire INT 48k x2 x4 SEL 3 4 1 2 5 6 7 8 aes spdif tos in aes spdif tos SRC SPDIF TOS FRONT aes spdif c...

Страница 24: ...6 we send the signal to a broadcast section SETUP EXAMPLES 22 Example 3 PA setup FORMAT CONVERTER PATCHBAY FIREWIRE IO digitalkonnekt x32 3 4 3 4 3 4 1 2 1 2 1 2 5 6 5 6 5 6 7 8 7 8 7 8 adat adat ada...

Страница 25: ...1 2 LED indicates that a signal is present on AES 1 2 Sample Rate conversion is activated on channels pair 1 2 AES channels 1 2 is routed to the master EQ via AES 3 4 out and also via 5 6 to broadcas...

Страница 26: ...t the DVD player on the same channel pair as the Reverb 4000 In the AES SPDIF TOS input select section you will then have to decide which device that should be routed for the current application It is...

Страница 27: ...it 3 4 1 2 5 6 7 8 aes spdif tos in aes spdif tos SRC SPDIF TOS FRONT aes spdif clock master LOCK SIG 1 2 3 4 5 6 7 8 Clock In Pro Tools you select AES EBU as clock source Digital Konnekt x32 then act...

Страница 28: ...ased on this sample rate to all devices in the setup There can be one and only one clock master in a digital setup and you cannot select your computer here However the Clock Master device may sync to...

Страница 29: ...electronic com Press Click here to download the latest version and download the full installer Run the installer Updating firmware Once the installer has been run see above the latest version of firmw...

Страница 30: ...kHz 30 PPM 43 to 193 kHz jitter rejection at all rates JET technology in TC DICE II 3 dB 10 Hz 100 dB 600 Hz 1 ns peak BW 700 Hz to 100 kHz 0 5 of sample period 50 to 50 of sample period 0 03 0 05 0...

Отзывы: