- 23 -
Data Format
(not changeable):
8-N-1. 8 bit data, no parity, 1 stop bit.
Baud Rate:
(select it from the pull-down field on page 21)
300bps, 2.4K, 4.8K, 9.6K, 19.2K, 38.4K, 48K, or 57.6K can be selected.
19.2K is the default setting.
Delay Setting:
10msec (default)
User Options
: 1. The user can leave the default delay setting of 10msec for any baud rate setting. Or
2. If the user chooses to change the delay setting, then the following minimum delay
settings apply to the given baud rates as shown on Table 1, below.
Transmit Filter Enable
(Telnet Mode only)*:
Change CR/LF(Carriage Return and Line Feed) character pairs into a single CR.
Default Value: Unchecked
Telnet Timeout Enable
(Telnet, Gateway, or Reverse Telnet Mode only)*:
Enable the Telnet Timeout option.
In Telnet Gateway Mode, the TC3420 will disconnect the link between itself and the remote telnet client
if there is no data being send by the TC3420 for 30 seconds or the time specified in the Telnet Timeout
field below.
In Reverse Telnet Mode, the TC3420 will disconnect and reconnect the link between itself and the
remote telnet server if there is no data being send by the TC3420 for 30 seconds or the time specified
in the Telnet Timeout field below.
Default Value: Checked
Telnet Timeout
(Telnet Mode only)*:
1 - 6000 seconds.
Default Value: 30
Click the "Undo" button or browser's "Back" button to cancel all the changes
Click the "Submit" button to save the changes.
*
Note:
Not used, for future release.