Chapter 3 - Troubleshooting

General

Alarm conditions occur whenever an optical problem or "fault" is detected by the TC2100.  Under normal

operation, all LEDs should be "On" (either solid or blinking), with the exception of the "ALARM" LED.

All LEDs are "Off"

If no LEDs are lit on the unit, check the DC power supply, terminal block connector plug, and/or power

source.

Alarm LED

When there is an alarm condition, the Alarm LED should be on solidly and at least one additional LED will

flash.  The following fault conditions will cause the Alarm to be triggered:

1.

Optic signal lost from "RxA" or "RxB."  “Sync-A” or “Sync-B” LED will be flashing.

2.

Optic signal is marginal, which causes invalid data packets to be received.  The "Sync-A" or "Sync-B"

LED will also be "Off."

3.

Optic overdrive can cause the "Sync-A" or "Sync-B" LED to turn "Off," although optic "A" or "B" still

receives a valid signal.

4.

One (or more) of the external DIP switches is in the "On" position.

5.

The Anti-Streaming function has been activated.

6.

On the Master unit, the "A-Ring" or "B-Ring" is incomplete.

7.

On the Slave units, a data wrap condition exists.  The "A2B" or "B2A" LED is flashing, indicating the

wrap condition, and the "LPA" or "LPB" LED will also be blinking.

Optic Cable Types

Conventionally, fiber optic cable with yellow-colored insulation is used for single mode applications; gray or

orange-colored insulated cable is for multimode use.  If multimode cable is used in a single mode application,

the test results could be erroneous and confusing.

Calculating the Loss on the Fiber

The fiber optic link and/or the connectors are frequently the source of communication problems.  If problems

are present, check the optic connectors and the integrity of the link first.  Ideally, the link should be calibrated

for total loss after the installation has been completed.  This will accomplish two things: (1) it will verify that

the total loss of the link is within the loss budget of the device and (2) it will provide a benchmark for future

testing.  For example, a system that has been tested as having 6dB of signal loss when installed should not

suddenly test out as having a loss of 10dB.  If this were the case, however, the fiber link or connector would

probably be the source of the problem.

*These numbers are listed for reference only.  We recommend an OTDR reading be used to determine actual link loss.

These are the reference values we use to calculate the loss on the fiber:

Multimode 850nm

:

3 dB loss per km on 62.5/125 µm cable*

Multimode 1300nm

:

2 dB loss per km on 62.5/125 µm cable*

Single Mode 1300nm

:

0.5 dB loss per km on 9/125 µm cable*

Single Mode 1550nm

:

0.25 dB loss per km on 9/125 µm cable*

Содержание TC2100

Страница 1: ...ions Inc reserves the right to change or modify the contents of this manual at any time without prior notification TC2100 RACK MOUNT STAND ALONE MULTI DROP DUAL MASTER Self Healing Ring FIBER OPTIC MO...

Страница 2: ...Electrical Specifications 14 Pin Assignments 14 Fiber Optic Specifications 16 Transmission Distances typical 16 Launch Power Sensitivity 16 Chapter 2 Installation 17 Unpacking the Unit 17 Equipment Lo...

Страница 3: ...it can detect any one of four possible cable breakage conditions referred to as fault conditions as shown in Figure 4 The TC2100 can detect ring breakage on either the A Ring or B Ring When a cable br...

Страница 4: ...Host controller to a fiber optic signal and transmit that signal in both ring directions as shown in Figure 2 Figure 3 Ring Operation Under Normal Conditions The first Slave unit in the ring intercep...

Страница 5: ...ult Conditions Figure 6 Self Healing Function resulting from Optic Cable Breakage Figure 5 Data Wrap Condition due to Fault 2 or 3 As Figure 6 below illustrates should a cable breakage occur between S...

Страница 6: ...g and one for the B Ring The monitoring signal originates from the Master unit and travels along the A Ring and B Ring Each Slave relays the monitoring signal to the next unit If the monitoring signal...

Страница 7: ...en Slaves The TC2100 s link monitor consists of cable fault detection rings that are implemented between Slaves and between the Slave and Master units This monitor can detect cable breakage between an...

Страница 8: ...he source of the problem 2 The master unit is isolated from rest of the network 3 Both A ring and B ring break in more than one location which split the network into half The Dual Master mode is desig...

Страница 9: ...ignals to rest of the units on the network In the mean time unit 2 and unit 4 will activate self healing feature which wraps the data to avoid the broken data link and the network will function normal...

Страница 10: ...he main master unit unit 1 is only able to transmit data to unit 2 However with unit 3 in Dual Master Mode it can be a backup master by connecting to a host controller This way unit 3 will become a ma...

Страница 11: ...Indicates a response msg from a remote device on Channel 2 when lit TC2100 OPTIC FAULT LEDs A2B When lit indicates a data wrap condition exists and the unit is routing RxA data to TxB not lit for sing...

Страница 12: ...unit received an invalid packet 3 The Anti streaming timer has expired slave only 4 The unit is in a diagnostic testing mode PWRA Indicates a 12V DC power supply is connected to the power jack A inpu...

Страница 13: ...t once the jabbering subsides The Anti Streaming Timer can be disabled by sliding both switch 1 and switch 2 of Slave s internal DIP switches SW1 to the left Off position Setting Up RS 485 Transition...

Страница 14: ...he electrical signal interface is connected to the host or RTU via a DB25 female connector at the rear panel of the TC2100 The RS 232 DTE DCE and RS 422 485 DB25 pin assignments are as illustrated in...

Страница 15: ...Figure 14 2 wire RS 485 Connection Logic Diagram For RS 422 and RS 485 4 wire interfaces pins 2 14 are inputs while pins 3 16 are outputs Figure 15 4 wire RS 422 RS 485 Connection Logic Diagram For 2...

Страница 16: ...o 3km are typical over Multimode fiber at 850nm and 4km at 1310nm Distances to 35km are typical over Single Mode fiber at 1310nm Contact factory for longer distance requirements Laser version Launch P...

Страница 17: ...lug is a terminal block connector with positive negative polarity indicated on the rear panel of the unit Alternate power sources are available as an option see Chapter 6 Specifications Installation P...

Страница 18: ...linking Optic Cable Types Conventionally fiber optic cable with yellow colored insulation is used for single mode applications gray or orange colored insulated cable is for multimode use If multimode...

Страница 19: ...n 1 Set up the bench test as shown in Figure 16 At the Master unit turn On the SIG GEN by sliding ESW3 downward The BRD 1 and BRD 2 LEDs on the TC2100 Master should start blinking The BRD 1 and BRD 2...

Страница 20: ...ure Set up the bench test as shown in Figure 17 Set ESW2 front panel to the down On position and the Alarm LED should start flashing Set the BERT tester up as a DTE device set the tester up as a DCE d...

Страница 21: ...the rear of the TC2100 Unscrew the two flathead screws on the TC2100 s front panel Gently slide the unit out of the housing Set the switch 3 of the internal DIP switch SW1 to the right On position and...

Страница 22: ...optional Procedure Set up the bench test as shown in Figure 19 Using a small jumper wire short pin 2 to pin 3 for an RS 232 interface at Slave 1 s DB25 connector or switch ESW1 RMTLB to the down posit...

Страница 23: ...s connector pins 2 4 for an RS 232 interace from the SCADA host On the Slave units the BRD 1 BRD 2 are the received broadcast signals originating from the SCADA host The RSP 1 RSP 2 stand for Respons...

Страница 24: ...S 485 2 or 4 wire System Bit Error Rate 1 in 109 or better Visual Indicators BRD 1 BRD 2 RSP 1 RSP 2 LPA LPB TxA TC2100 only TxB TC2100 only A2B TC2101 only B2A TC2101 only RxA Sync A RxB Sync B PWRA...

Страница 25: ...Inc Buyer shall bear the risk of loss until all goods authorized to be returned are delivered to TC Communications Inc TC Communications Inc shall not be liable for any inspection packing or labor co...

Страница 26: ...onsible for delays or non deliveries directly or indirectly resulting from or contributed to by foreign or domestic embargoes seizure fire flood explosion strike act of God vandalism insurrection riot...

Отзывы: