24
7. TECHNICAL SPECIFICATIONS
Parameter
PSC1600-12-60
PSC1800-24-35
Inverter stage
Output power
1)
Pnom
1300W
1400W
P10minutes
1600W
1800W
Psurge
2500W
3000W
Output voltage / frequency
230Vac ± 2% / 50Hz ± 0.05%
Output waveform
True sinewave (THD < 5%
1)
@ Pnom)
Input voltage (± 3% tolerance): Nominal
12V
24V
Range
10.5
2)
– 16Vdc
21
2)
– 32Vdc
Maximum efficiency
92%
94%
No load power consumption
3)
[ASB]
< 10W [2.0W]
< 12W [2.0W]
Charger stage
AC input voltage
185 – 270Vac / 45 – 65Hz / PF > 0.95
Maximum continuous charging current
4)
60A
35A
Standard charge voltage (bulk / float @ 25°C)
14.3V / 13.3V
28.6V / 26.6V
Charge algorithm or program
IUoUoP, intelligent 4 stage, temp. comp.
AC Transfer switch
Maximum continuous current
16Arms
Transfer time (typical)
0ms (inv. → mains) / < 5ms (mains → inv.)
General
TBSLink enabled
Yes
Protections
high/low battery voltage, high temperature,
overload, short circuit,
high ripple voltage and low AC input voltage
DC connections
Two wires, length 1.5 meters, 35mm
2
AC connections
Screw terminals
Enclosure body size
351 x 210 x 114mm
Total weight
10.7kg
Protection class / Op. temp. / Storage temp.
IP21 / -20°C .. +50°C / -40°C .. +80°C
Standards
CE marked meeting EMC directive
2004/108/EC and LVD 2006/95/EC
complying with EN60335-1, EN60335-2-29
and RoHS 2002/95/EC
Note : the given specifications are subject to change without notice.
1) Measured with resistive load. Power ratings are subject to a tolerance of 10% and are decreasing as temperature rises with a rate of
approx. 1.2%/°C starting from 25°C.
2) Undervoltage limit is dynamic. This limit decreases with increasing load to compensate the voltage drop across cables and connections.
3) Measured at nominal input voltage and 25°C
4) At higher ambient temperatures, maximum output current shall be reduced automatically