![TBEI Rugby LR-2355 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/tbei/rugby-lr-2355/rugby-lr-2355_installation-and-operation-manual_823557005.webp)
Model LR-26C, LR-623, LR-28A, & LR-2355 Hoist Installation and Operation Manual
Stock No. 036268
Page 5 of 27
TABLE A
LR-26C APPLICATION CHART
BODY
LENGTH
OVERHANG
CAPACITY
40° DUMP
ANGLE
CAPACITY
45° DUMP
ANGLE
CAPACITY
50° DUMP
ANGLE
10’
12”
18.5 TONS
16.8 TONS
10’
0”
16.6 TONS
14.8 TONS
13.4 TONS
11’
12”
18.4 TONS
16.5 TONS
14.9 TONS
12’
24”
20.8 TONS
18.5 TONS
16.8 TONS
12’
12”
16.6 TONS
14.8 TONS
13.4 TONS
12’
0”
NR
12.3 TONS
11.2 TONS
13’
42”
27.7 TONS
24.7 TONS
22.4 TONS
13’
30”
20.8 TONS
18.5 TONS
16.8 TONS
13’
24”
18.4 TONS
16.5 TONS
14.9 TONS
14’
42”
23.7 TONS
21.2 TONS
19.2 TONS
14’
36”
20.8 TONS
18.5 TONS
16.8 TONS
14’
30”
18.4 TONS
16.5 TONS
14.9 TONS
14’
24”
NR
14.8 TONS
13.4 TONS
14’
12”
NR
12.3 TONS
11.2 TONS
15’
48”
23.7 TONS
21.2 TONS
19.2 TONS
15’
42”
20.8 TONS
18.5 TONS
16.8 TONS
15’
36”
NR
16.5 TONS
14.9 TONS
16’
48”
NR
18.5 TONS
16.8 TONS
16’
42”
NR
16.5 TONS
14.9 TONS
LR-26C
REVERSE STANDARD
M DUMP
ANGLE M
102.25” 40° 104.25”
91.25” 45° 93.25”
82.50” 50° 84.50”
DUMP CLASS: 50
CONVERSION CLASS: E
7.13” Mounting Height
6” long beams recommended
Capacities are based on the following:
1.
Water level non-diminishing loads.
2.
The hydraulic relief pressure set at the maximum 3,200 psi (see page 2 of this manual).
IMPORTANT:
Because of variations in applications, the data contained in this sheet is provided only
as a general guide.
IMPORTANT:
NR stands for Not Recommended. Contact TBEI-Rugby Engineering before using in
an application listed as NR.