4.1 Wiring diagram 
 

 
 
4.2 Port definitions 

 
 

No.  Label 

Description 

No. 

Label 

Description 

Live line of AC input 

12 

T1 

Temperature sensor port 

PE 

Earth line of AC input 

13 

T2 

Neutral line of AC input 

14 

HK 

Battery equilization 

interface 

NC 

Reserved 

15 

HG 

HOK 

Dry contacts 

16 

VG 

VL 

17 

B- 

Battery- 

VH 

18 

B+ 

POK 

19 

VO- 

DC outputs 

VC 

20 

VO- 

10 

RS485 port 

21 

VO+ 

11 

22 

VO+ 

5

T1 T2

6

7

8

9

10 11 12 13

14 15

16 17

18 19

20 21

4

3

2

1

22

NC HOK VL VH POK VC

A

B

 HK  HG VG B-

B+

VO-

VO+ VO+

VO-

Load

Battery

K2 K3

Temperature

sensor port

Signal output

23

24

25

26

CHG DCHG EQ Fault

27

28

ON

EQ

Battery

OFF

ON

OFF

  N

AC_N

 PE

   L

Fuse

AC_L

Communication port

Содержание iDU500-24

Страница 1: ...iDU series User Manual TBB Power Co Ltd iDU series DC POWER SUPPLY Version A1 0 Date Feb 2017...

Страница 2: ...User Manual TBB Power Co Ltd WARNING FIRE HAZARD SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON COMBUS TIBLE SURFACE ONLY CAUTION THE DC AND AC BREAKER MUST HAVE BEEN TURNED OFF BEFORE SERVICING MADE...

Страница 3: ...re of installations This manual is for anyone intending to install our equipment General Instruction Thanks for choosing our products and this manual were suitable for iDU series This chapter contains...

Страница 4: ...General Precaution 1 1 3 Precaution regarding battery operation 1 2 Introduction 2 2 1 Schematic Diagram 2 2 2 Charging Curve 3 2 3 Mode Name 3 3 3 Structure 4 4 O Op pe er ra at ti io on n 5 4 1 Wir...

Страница 5: ...re all cables selected with right gauge and being connected well Smaller diameter and broken cable are not allowed to use 1 2 3 Please do not put any inflammable goods near to charge controller 1 2 4...

Страница 6: ...s the energy to the loads iDU alarms via dry contact When battery discharged until the low voltage protection level iDU cut off the output of battery and alarms via dry contact When the battery in the...

Страница 7: ...utput voltage Battery type Product series 1 2 3 4 5 6 Output type Communication function No Value Description 1 i i means with RS484 communication 2 N A One output D Two outputs 3 DU Product series 4...

Страница 8: ...iDU series User Manual TBB Power Co Ltd 4 3 3 Structure 168 110 70 158 4 5 112 5 10 148 10 45...

Страница 9: ...AC input 14 HK Battery equilization interface 4 NC Reserved 15 HG 5 HOK Dry contacts 16 VG 6 VL 17 B Battery 7 VH 18 B Battery 8 POK 19 VO DC outputs 9 VC 20 VO 10 A RS485 port 21 VO 11 B 22 VO 5 T1 T...

Страница 10: ...upply separately Flashing Charging 24 DCHG Green ON Discharged 25 EQ Yellow ON Equilization 26 Fault Red ON Fault Flashing Battery low voltage Reverse Over temp No Label Operation Description 27 EQ Lo...

Страница 11: ...ure 40 70 full load at 60 and derating 60 at 70 Communication RS485 Dry contact AC grid fault Battery low voltage unit fault and Battery equilization Battery low voltage protection VDC 22 44 Battery E...

Страница 12: ...iDU series User Manual TBB Power Co Ltd 8 TBB Power Co Ltd Web www tbbpower com Tel 86 592 5212299 Fax 86 592 5796070 Email service tbbpower com...

Отзывы: