background image

                                               

                                                       

Bi1248

1200

 

User

 

Manual

 

 

   

                                                                     

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TBB

 

Power

 

Co.,

 

Ltd

 

Web:

 

www.tbbpower.com

 

Tel:

 

+86

592

5212299

 

Fax:

 

+86

592

5796070

 

Email:

 

[email protected]

 

Содержание Bi1248-1200

Страница 1: ...Bi1248 1200 User Manual TBB Power Co Ltd Bi directional Converter Charger Bi1248 1200 User Manual Version A1 0 Date Dec 2019...

Страница 2: ...0 User Manual TBB Power Co Ltd WARNING FIRE HAZARD SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON COMBUS TABLE SURFACE ONLY CAUTION THE DC AND AC BREAKER MUST HAVE BEEN TURNED OFF BEFORE SERVICING MAD...

Страница 3: ...or choosing our products and this manual were suitable for DC DC Bi directional Converter Bi1248 1200 This chapter contains important safety and operation instructions Read and keep this User Guide we...

Страница 4: ...nstallation Configuration 5 4 1 Unpacking inspection 6 4 2 Installation requirements 5 4 3 Cable preparation 5 5 Installation 5 5 1 Installation recommendations and operations 6 5 1 1 Installation dra...

Страница 5: ...therwise Bi1248 1200 would be overheating To avoid fire and electric shock make sure all cables selected with right gauge and being connected well Smaller diameter and broken cable are not allowed to...

Страница 6: ...voltage is lower than 12 8V this device will stop working Smart alternator Euro 6 Through dip switch this device can be set to smart alternator mode After choosing this mode IGN signal or similar sig...

Страница 7: ...tor Multiple battery chemical can be chose including lithium battery TBB premium II multiple stages charging algorithm Built in automatic temperature and voltage compensated charging Thermal controlle...

Страница 8: ...Bi1248 1200 User Manual 4 3 Structure 3 1 Dimension 306 3282 8 170 291 6 85 200 4 5 301 6 Dimension 306 3 200 85mm Weight 3kgs...

Страница 9: ...ethod air cooling Altitude 2000m or less meeting the derating requirements of GB3859 2 93 4 3 Cable and Fuse preparation Please refer to the table below for cable and fuse specifications Model Connect...

Страница 10: ...off the power switch or external control signal to prevent Bi1248 1200 from working due to which may cause sparkling during the wiring process Please select the appropriate location with adequate vent...

Страница 11: ...is 100A 3 12V terminal Positive terminal of starter battery the maximum current is 200A 4 BAT terminal Negative terminal of starter battery the maximum current is 100A 5 BAT terminal Negative termina...

Страница 12: ...1 2 Battery Type setting OFF OFF AGM default OFF ON GEL ON OFF LFP ON ON OTHER 3 Alternator setting OFF Normal alternator ON Smart generator Euro 6 4 5 System working mode OFF OFF Stand alone mode ON...

Страница 13: ...rminal BAT first and then connect the positive terminal 48V of the auxiliary battery and the positive terminal 12V of the starter battery respectively Connect one end of the negative cable to the term...

Страница 14: ...RY_DO_NO1 Dry contact output normally open contact 10 DRY_DO_NO2 11 DRY_DI_NO1 Dry contact input normally open contact 12 DRY_DI_NO2 13 TEMP_BAT1 Service battery temperature sampling line 14 TEMP_BAT1...

Страница 15: ...is strictly prohibited Check if the voltage and temperature compensation lines have been connected to the positive terminal of service battery If the generator is a smart generator confirm that the D...

Страница 16: ...ndby Off others Boost mode Green On 12V battery is normal 12V battery charges 48V battery Flash standby Off others Alarm Orange Flash overheating of the radiator over temperature of the battery overvo...

Страница 17: ...ard battery charging curve Battery types and bulk charging absorption charging voltage Table 8 Service battery types and bulk charging absorption charging voltage No Battery types Bulk charging voltag...

Страница 18: ...e rating curve This device has built in intelligent temperature control and will reduce its output power in case of high working temperature reached Figure 8 Bi1248 1200 internal temperature and outpu...

Страница 19: ...25A 100A Efficiency Max 94 Full load 91 Standby consumption 2mA Protection Input overvoltage alarm 14 9Vdc protection 16Vdc alarm 59 6V protection 60Vdc Output overvoltage alarm 59 6V protection 60Vd...

Страница 20: ...Bi1248 1200 User Manual 16 TBB Power Co Ltd Web www tbbpower com Tel 86 592 5212299 Fax 86 592 5796070 Email service tbbpower com...

Отзывы: