background image

                                                                                                      Apollo Maxx User Manual 

2.2  Structure 

2.2.1 Front 

 

Apollo Maxx 2.0M, Apollo Maxx 2.0S, Apollo Maxx 3.0M, Apollo Maxx 3.0S

 

 

Apollo Maxx 5.0S

 

Figure 2-1 Front View of the All in One Solar Inverter Structure 

Содержание APOLLO MAXX Series

Страница 1: ......

Страница 2: ...Apollo Maxx User Manual WARNING HIGH VOLTAGE INSIDE CAUTION THE DC FUSE MUST HAVE BEENTURNED OFF BEFORE SERVICING MADE IN CHINA...

Страница 3: ...l in One Solar Inverter This chapter contains important safety and operation instructions Read and keep this User Guide well for later reference The Apollo Maxx All in One Solar Inverter needs to be i...

Страница 4: ...Assist 7 2 3 4 System Working Mode 8 2 3 5 Built in Load Management 8 2 3 6 Powerful and Reliable Inverter 8 2 3 7 Professional Battery Charger 8 2 3 8 Transfer 11 2 3 9 Protect Function 11 2 3 10 Com...

Страница 5: ...otherwise the Apollo Maxx All in One Solar Inverter would be overheating To avoid the fire and the electric shock make sure all cables selected with right gauge and connected well Smaller diameter an...

Страница 6: ...demanding appliances such as air conditioner water pump washing machine freezer etc With the function of power assist power control it can be used to work with a limited AC source such as generator or...

Страница 7: ...pollo Maxx User Manual 3 2 2 Structure 2 2 1 Front Apollo Maxx 2 0M Apollo Maxx 2 0S Apollo Maxx 3 0M Apollo Maxx 3 0S Apollo Maxx 5 0S Figure 2 1 Front View of the All in One Solar Inverter Structure...

Страница 8: ...rol panel ON OFF button Operation button Figure 2 2 All in One Solar Inverter Control Buttons 2 2 3 Connection compartment Apollo Maxx 2 0M Apollo Maxx 2 0S Apollo Maxx 3 0M Apollo Maxx 3 0S Apollo Ma...

Страница 9: ...rgy etc ComSync In Parallel synchronous communication input CAN ComSync Out Parallel synchronous communication output CAN EPO Dry contact input control emergency power off ComSYS System communication...

Страница 10: ...Apollo Maxx User Manual 6 Apollo Maxx 5 0S Figure 2 4 Power terminal 2 2 4 Dimension Apollo Maxx 2 0M Apollo Maxx 2 0S Apollo Maxx 3 0M Apollo Maxx 3 0S...

Страница 11: ...for system expansion or to construct a micro grid system For single phase system max three units can be connected in parallel For three phase system max seven units can be connected together 2 3 3 Po...

Страница 12: ...en better to what you can get from your utility grid Pure sine wave can guarantee the correct function of the sensitive equipments computer laser printer TV etc Also your home appliances such as fridg...

Страница 13: ...recommended by the battery manufacture are in fact ONLY applied at 20 25 The Bat sample cable battery temperature and voltage sensor supplied with Apollo Maxx measures the temperature of the battery...

Страница 14: ...ormal charging During equalization the battery generates potentially flammable gases Follow all the battery safety precautions listed in this guide Ventilate the area around the battery thoroughly and...

Страница 15: ...o Maxx All in One Solar Inverter is automatically connected to the earth when no external AC sources is available Once the external AC sources presents the ground relay will open You can disable this...

Страница 16: ...on To prevent the permanent damage caused by the over discharge of battery the equipment will automatically cut off the output according to the low voltage SOC protection point set by the user 2 3 10...

Страница 17: ...Storage temperature 40 70 Cooling Force fan Relative humidity in operation 95 without condensation Altitude 2000m 3 1 Recommended DC cables Please find the following minimum wire size If the DC cable...

Страница 18: ...seconds to turn on the inverter into the standby mode the power LED will light up and the LCD will enter into the self diagnostic mode Step 3 Wait in the standby mode for 30 seconds then press the On...

Страница 19: ...and a LCD display indicating the operating status and input output power information LCD ESC UP DOWN ENTER LCD Operation Button LED Indicator Button Function To exit the setting mode or confirm the fa...

Страница 20: ...Flashing Power Assist mode Charge Green Solid on The battery is Charging Flashing The battery is fully Charged Fault Red Solid on Fault occurs Flashing Warning occurs 5 2 LCD Display Icons Icon Funct...

Страница 21: ...ton to view the warning code Fault flashing every 1 second Press ESC button to view the warning code Output Information Indicates output voltage output frequency load percent load in Watt load in VA a...

Страница 22: ...ograms Then press the ENTER button to confirm the selection of the setting programs or press the ESC button to exit the setting mode After confirm the selection of the setting programs press the UP an...

Страница 23: ...t once Default 0 05 Fault unlock 1 Press ENTER to trigger the effect once Default 0 06 Fan dedusting 1 Press ENTER to trigger the effect once Default 0 07 Parallel address 1 Max U 3 V 2 W 2 Default 1...

Страница 24: ...imum AC in frequency 42 49Hz 50Hz 52 59Hz 60Hz Step 1Hz Default 45Hz 18 AC wave harmonic adaption 0 Normal 1 Weak AC Input Default 0 21 AC in connect delay 20 990s Step 10s Default 20s 23 Low AC in al...

Страница 25: ...oltage Step 0 1V Default 13 6V 12V cell Bulk charging voltage 34 Low battery alarm voltage 10 0 13 0V Step 0 1V Default 11 0V 12V cell Low battery protect voltage 35 Low battery protection voltage 9 5...

Страница 26: ...arm threshold 15 90 Step 1 Default 15 Low SOC protect threshold 44 Low SOC protect threshold 3 50 Step 1 Default 5 Low SOC alarm threshold 45 Battery over temperature threshold 25 65 Step 1 Default 55...

Страница 27: ...SOC enough threshold 30 99 Step 1 Default 80 Low SOC alarm threshold 1 Mode Setting 60 Common neutral line 0 Disable 1 Enable Default 0 only in standby mode 61 Connect Neutral to GND Inside 0 Disable...

Страница 28: ...batteries for 24V and 48V system 69 BGK_RESTART 1 Press ENTER to trigger the effect once Default 0 70 Dry contact function 0 Default 1 User Define Default 0 71 Dry contact 1 define 0 Ubat Low 1 OverL...

Страница 29: ...Default 0 76 Error restart enable 0 Disable 1 Enable Default 0 77 LCD backlight keep on enable 0 Disable 1 Enable Default 1 Version 80 Software version Ready only 81 Firmware version Ready only 82 MP...

Страница 30: ...installer in case it still exists 05 The heat sink s temperature is too high Check and assure the inverter has good ventilation 06 The transformer s temperature is too high Too high ambient temperatu...

Страница 31: ...high Check fan ventilation 24 The heat sink s temperature is too high Too high ambient temperature 25 Abnormal auxiliary power supply Restart the MPPT Contact the installer in case the error still exi...

Страница 32: ...ization overtime 14 The system mode and the parameter setting do not match Check the parameter setting Lithium battery 15 Abnormal AC output in the parallel system or the three systems Check the outpu...

Страница 33: ...e system 6 2 3 BMS Warning Warning Code Description 40 The lithium module is over voltage protection 41 The lithium module is under voltage protection 42 The lithium module s temperature is too high 4...

Страница 34: ...voltage alarm 81 Battery under voltage alarm 82 The single battery voltage is lower than the average voltage 83 The single battery voltage is higher than the average voltage 84 The battery temperature...

Страница 35: ...00W 4000W 6000W PV open circuit voltage 150V MPPT voltage range 65V 145V MPPT charger maximum efficiency 98 MPPT efficiency 99 5 Protection a output short circuit b overload c battery voltage too high...

Страница 36: ...Apollo Maxx User Manual 32...

Отзывы: