M12-400 Lithium Battery User Manual
19
Do not connect the (-) terminal first, otherwise it may cause a short circuit!
Step 6: Remove the protective cover of the lithium battery (-) terminal.
Step 7: Connect the parallel cables L7(negative) between the lithium batteries. Torque
requirement: 15N.M . Make sure the wiring is tight and firm.
Step 8: Connect the cable L3 between the (-) terminal of the load or charger and the (-) terminal of
lithium battery. Torque requirement: 15 N.M .Make sure the wiring is tight and firm.
Step 9: Install the protective cover of the lithium battery (-) terminal.
3.6.3 Communication cable wiring
Step 1: Connect the communication cable L8 between lithium batteries (1#~4#);
Step 2: Please use UTP standard network cable to connect the CAN/RS485 communication
interface of the 1# lithium battery and the corresponding interface of the inverter or system.
Step 3: Please connect the Display communication interface of the #1 lithium battery to the MCK
display communication interface.
Note: If you use the MCK display panel, do not connect to the dry contact connector
(provided by TBB).
Note: Please refer to section 3.5 for battery wiring of MCK and remote switch if it is
equipped with TBB inverter.
3.6.4 Power ON and Power OFF
Power ON the battery: please turn the Power switch on the #1 lithium battery to the ON position;
and turn the rocker switch on the MCK to the "I" position;
Power OFF the battery: please turn the Power switch on the #1 lithium battery to OFF position; or
turn the rocker switch on MCK to "O" position;
Note: Please refer to section 3.5 for lithium battery power on and off if it is equipped with
TBB inverter.
3.7 Disconnect the lithium battery
Step 1: Please turn OFF the Power switches on all lithium batteries.
Step 2: Please turn off all devices or chargers connected to the lithium battery.
Step 3: Please disconnect the cables between the negative pole of the lithium battery and the
load or charger.
Step 4: Please disconnect the cables between the positive pole of the lithium battery and the
load or charger.
Note: If you use the MCK display panel, you need to disconnect the network cable between