TBB power Energier Apollo Series Скачать руководство пользователя страница 1

                                                                                                                     

Energier Apollo User Manual 

 

TBB Power Co.

Ltd 

                                                           

 

Energier Apollo series 

ALL-IN-ONE for Solar Hybrid-system 

 

 

Version A1.5 

Date: March. 2018 

 

 

 

Содержание Energier Apollo Series

Страница 1: ...Energier Apollo User Manual TBB Power Co Ltd Energier Apollo series ALL IN ONE for Solar Hybrid system Version A1 5 Date March 2018...

Страница 2: ...n writing TBB Power Co Ltd Take no warranty as to the accuracy sufficiency of suitability of any technical or other information provided in this manual or other documentation Assumes no responsibility...

Страница 3: ...tage or voltage of battery is same to the nominal input voltage of this inverter 2 Please connect positive terminal of battery to input of the inverter 3 Please connect negative terminal of battery to...

Страница 4: ...r 7 2 5 Transfer 7 2 6 Multi battery chemical available 7 2 7 Manual Equalization 8 2 8 Settable Low voltage disconnect level 8 2 9 Weak Grid 8 2 10 Solar mode 8 2 11 Power Save Mode PS mode 9 2 12 AE...

Страница 5: ...Mode 20 4 3 Solar Mode 20 4 4 Low Voltage disconnect LVD 21 4 5 Battery Type 21 4 6 Equalization EQ 21 4 7 Power Save mode PS mode 22 4 8 Grid charger 22 4 9 AC input current setting 23 5 Pre Installa...

Страница 6: ...off solar charge controller 41 7 9 Power Saving mode 42 7 10 Performing De sulphation Charging 42 8 Specification 46 9 Trouble Shooting 49 9 1 LED indicator on front panel and audible alarm 49 9 2 LED...

Страница 7: ...t expose to dust rain snow or liquids of any type it is designed for indoor use DO NOT block off ventilation otherwise the Energier Apollo would be overheating 1 2 2 To avoid fire and electric shock m...

Страница 8: ...Power Co Ltd 2 1 3 4 REMOVE all personal metal items such as rings bracelets necklaces and watches while working with batteries Batteries can cause short circuit current high enough to make metal mel...

Страница 9: ...arious hybrid power system The product was delivered with following equipment Energier Apollo User s manual VS battery voltage sensor TS battery temperature sensor RCH Remote module optional Digital S...

Страница 10: ...ription Energier Apollo is a powerful unit integrated multiple functions including a high performance true sine wave inverter a powerful battery charger a solar charge controller a high speed automati...

Страница 11: ...your utility grid Pure sine wave can guarantee the correct function of sensitive equipment computer laser printer TV etc or most demanding inductive load Also your home appliances will work smoother...

Страница 12: ...manufacture are in fact ONLY applied at 20 25 The TS battery temperature sensor supplied with Energier Apollo measures the temperature of battery and automatically makes adjustments at real time to p...

Страница 13: ...voltage at the output as AC input In case of AC input failure or exceeding the minimum requirement Energier Apollo will initiate a quick switching to inverter mode about 8ms of which will guarantee a...

Страница 14: ...d controlled battery condition For different application the user intended to have different low voltage disconnection level For example for solar application user intended to have less DOD to prolong...

Страница 15: ...and software making it robust and reliable Overload protection Both of charger and output are being protected against overload by software In case of the Energier Apollo is too long or too heavily ov...

Страница 16: ...n this port It can be connected to the computer running the configuration software 2 15 RCH remote module optional device Through RCH remote module following information and function can be obtained L...

Страница 17: ...r with Digital Shunt Cyber can be bought to be connected to the Energier Apollo for abundant data Monitoring with all real time data Battery State of Charge monitor Configuration Active Alarm info 2 1...

Страница 18: ...00W 16 1600VA 1500W 20 2000VA 1700W YY 30 Rated charge current 30A 35 35A 40 40A 50 50A Z L Rated DC voltage 12V M 24V CH1350L Energier Apollo series Rated DC voltage 12V Rated output power 1300VA 120...

Страница 19: ...Energier Apollo User Manual TBB Power Co Ltd 13 3 Structure 3 1 Product drawing 3 1 1 Energier Apollo CH1035L CH1350L CH1630M CH2040M 3 1 2 RCH remote 3 1 3 Cyber and Digital Shunt Cyber Digital Shunt...

Страница 20: ...Co Ltd 14 3 2 Product size 3 2 1 Energier Apollo CH1035L CH1350L CH1630M CH2040M 3 2 2 RCH remote 4 M3 2 9 2 70 2 4 5 6 75 56 06 138 08 122 58 6 46 130 4 M3 2 9 2 70 2 4 5 6 75 162 80 56 06 138 08 23...

Страница 21: ...Energier Apollo User Manual TBB Power Co Ltd 15 3 2 3 Cyber 3 2 4 Digital Shunt 135 31 4 28 59 111 14 6 31 4 59 50 17 100...

Страница 22: ...Panel A Main switch B PV cable connector MC4 connector C PV cable connector MC4 connector D Battery cable through hole E Grounding terminal F Battery cable through hole G Gland for AC output1 H Gland...

Страница 23: ...TBB Power Co Ltd 17 Central Panel A RS485 Interface H DC Fuses B BTS Interface I Battery terminal C Battery AH setting clock switch J Battery terminal D DIP Switches K AC Input terminals E Remote Inte...

Страница 24: ...ing on DIP switch Please always use Rapconfig software to read the latest configuration Loose screws and remove the top panel you will see the central panel where you can finish all the configurations...

Страница 25: ...current However please make sure the current did not exceed 0 2C 20 of battery capacity For example for model CH1035L with battery capacity of 12V 200AH If you choose battery capacity at 100AH you co...

Страница 26: ...connected 4 3 Solar Mode While the main dip switch is set as SOLAR MODE Dip Switch 2 can be used to set two different solar modes Solar hybrid mode is the default Solar Hybrid Mode Under this mode Ene...

Страница 27: ...11 7VDC 12V model 23 4VDC 24V model 4 5 Battery Type Please select the battery type at the DIP Switch 4 5 following please find the list of available battery type and charging voltage DS4 DS5 Battery...

Страница 28: ...u choose wrong battery type Energier Apollo won t delivery equalization charging program and will only deliver the battery type you chose Please refer to chapter 7 10 for details of performing equaliz...

Страница 29: ...ting upon inverter working under bypass mode and grid was powering the load the built in Grid charger will not be activated The battery will be charged only when solar is available The default setting...

Страница 30: ...in a location of Dry Clean Cool with good ventilation Working temperature 10 50 Storage temperature 40 70 Relative Humidity 0 95 non condensing Cooling Forced air 5 3 Wiring recommendation Please find...

Страница 31: ...ipment to your AC system at the same time as any other AC source such as the 230V external mains or a generator On the AC output side we recommend connecting the output from Energier Apollo to a suita...

Страница 32: ...Energier Apollo User Manual TBB Power Co Ltd 26 Step 2 Hang on Energier Apollo Step 3 Fix the unit on the wall with 4 M6 screw...

Страница 33: ...anual TBB Power Co Ltd 27 6 3 Connecting the cable Please make sure Energier Apollo is turned off before connection Otherwise high voltage could be present Loose the screw and remove the top panel Def...

Страница 34: ...battery cables through the holes at front panel clamping the cable terminal on cable Secure the battery cable on DC and DC terminals respectively making sure it is tightly screwed Connecting the PV c...

Страница 35: ...anel and the unit connector is less than 10M If the length is more than 10M please consider to extend the size of the cable to make sure the voltage decreasing caused by the cable length is less than...

Страница 36: ...ough corresponding Glands and connect it on AC output block Terminals are marked as L line N neutral and PE earth Making sure it is tightly screwed There are two groups of AC output on Energier Apollo...

Страница 37: ...are marked as L line N neutral and PE earth Making sure it is tightly screwed Please double check the AC input and AC output was right after connection Wrong connection will cause permanent damage of...

Страница 38: ...ing the earth At the bottom of the connection cabinet showed as above there is a ground terminal Please connect it with EARTH or vehicle chassis by a proper gauge wire 6 4 Install the temperature sens...

Страница 39: ...ted to the minus of service battery and the positive of voltage sensor should be connected to the positive of service battery Wrong connection will damage the Energier Apollo Please secure the sensor...

Страница 40: ...the RS485 interface of Energier Apollo with the cable please refer to following figure 6 8 Install the Digital Shunt Digital Shunt could be installed either vertically on wall or horizontally on floor...

Страница 41: ...was available to put on the inverter Please refer to following picture of instruction Adding this net will deteriorate the heat radiating environment thus causing the rated power of inverter with de...

Страница 42: ...Energier Apollo User Manual TBB Power Co Ltd 36...

Страница 43: ...By pressing the button until beep was heard you can enter into setting Pressing Input Current Setting button again to choose the rating you would like to set After make the choice press Input Current...

Страница 44: ...e load level connected The Battery SOC LEDs on remote will reflect the battery condition which are 25 50 75 100 respectively from bottom 7 5 Switch on grid charger Then switch on the AC input power En...

Страница 45: ...minimum quality the Energier Apollo will perform charging Both LED charger and LED charging will illuminate on front panel The charger LED and AC in LED on remote will illuminate The Bulk LED Battery...

Страница 46: ...nate 7 7 Switch on solar charge controller Switch on the unit and PV input power the built in solar charge controller will start work after 30 seconds The Solar LED on front panel will illuminate The...

Страница 47: ...r the built in solar charge controller will stop charging Solar LED will extinguish Battery Charging Bulk Upon your PV input meet the minimum quality the Energier Apollo will perform charging Solar LE...

Страница 48: ...tically reduced Upon Energier Apollo being set in this mode Power Save mode LED on front panel will illuminate On remote upon Energier Apollo enter into power saving the Inverter LED on remote will fl...

Страница 49: ...t central panel you can initiate the de sulphation program manually Once you trigger on the EQ program Energier Apollo will perform de sulphation charging After you choose this program the charger wil...

Страница 50: ...ads Frequency Maximum once a month for heavily used battery you may wish to equalize your battery For battery with light service only need to be equalized every 2 3monthes Important Equalization can d...

Страница 51: ...Energier Apollo User Manual TBB Power Co Ltd 45 Battery type ONLY perform equalization to flooded and OPZS batteries Do not equalize GEL OPzV AGM or LFP batteries...

Страница 52: ...00 1600 2000 Power 30mins 25 W 900 1200 1500 1700 Cont power 25 VA 1 800 1200 1300 1600 Cont power 25 W 750 1100 1200 1300 Cont power 40 W 700 1000 1100 1200 Output voltage 2 230VAC 110VAC 2 Output fr...

Страница 53: ...264VAC 84VAC 132VAC Standard 194VAC 250VAC 97VAC 125VAC Battery types AGM GEL OPzV LFP Flooded Absorption time variable Temperature compensation 4mV cell Model No CH1035L CH1350L CH1630M CH2040M Solar...

Страница 54: ...with powder paint Dimension mm max 470 233 95 Net Weight KGs 10 5 11 6 11 7 12 Cooling Forced fan Protection IP20 IP40 with optional dust proof net Standard Safety EN62109 1 EN62109 2 EMC EN61000 3 2...

Страница 55: ...larm Charge Function Constant current Constant voltage flash flash Float flash Stop charging EQ flash flash flash Inverter Inverter on Power Save mode flash Alarm Mode PV high voltage beep continuousl...

Страница 56: ...ting status ON x OFF Status Function LED on remote panel Solar AC in Charger Inverter Fault other Charge Function Constant current Constant voltage flash Float flash EQ flash Inverter Inverter on Powe...

Страница 57: ...common failure which no maintenance on Energier Apollo was needed 9 3 1 No output first power on Phenomenon 1 No output at inverter mode No alarm Reason Battery low voltage Battery SOC bar Status of...

Страница 58: ...on Check battery voltage Check battery capacity Check battery LVD setting Phenomenon 2 No output long beep fault and inverter lights illuminate Reason Output shortcut Solution Remove output shortcut P...

Страница 59: ...eason 2 Wrong connection of N and PE of AC input Solution Correct the connection Reason 3 Check if using Generator as AC input Solution Change standard mode to weak grid mode through dip switch 1 at c...

Страница 60: ...ck if there is good ventilation on installation site check if fan was blocked 9 3 5 Normal mode and Power save mode keep changing over Reason 1 Energier Apollo work in power save mode but the load was...

Страница 61: ...TBB Power Co Ltd 55 TBB Power GmbH Web www tbbpower de Tel 49 211 6413 7948 Fax 49 211 6415 0003 Email info at tbbpower de TBB Power Co Ltd Web www tbbpower com Tel 86 592 5212299 Fax 86 592 5796070...