TBB power DDX1230 Скачать руководство пользователя страница 6

NEMO series battery to battery Charger

1

1. General Safety Instruction

1.1 Safety Instruction

As dangerous voltages and high temperatures exist within the charger, only qualified and

authorized maintenance personnel are permitted to open and repair it. Please make sure

the charger is turned off before attempting to dismantle or open it.

This manual contains information concerning the installation and operation of the charger.

All relevant parts of the manual should be read prior to commencing the installation. Please

follow the local regulations regarding electrical installations.

Any operation against safety requirement or against intended use, manufacture, safety

standard, will be out of the manufacturer warranty.

1.2 General Precaution

To avoid fire and electric shock and poor performance, make sure all cables that are

selected meet the wiring recommendations as per table 4-3 and table 4-4. Ensure a good

electrical connection. Smaller diameter and broken or poor-quality cable should not be

used. It is always recommended to suitably fuse the input and output of the Nemo.

Never place unit directly above batteries, gases from a battery will corrode and damage

charger.

Do not place battery over charger.

1.3 Precaution regarding battery operation

Use plenty of fresh water to clean in case battery acid contacts skin, clothing, or eyes and

consult with doctor as soon as possible.

The battery may generate flammable gas during charging. NEVER smoke or allow a spark

or flame in vicinity of a battery.

Do not put any metal tool or object on the battery, spark and short circuit might lead to

explosion.

REMOVE all personal metal items such as rings, bracelets, necklaces, and watches while

working with batteries. Batteries can cause short-circuit current high enough to make metal

melt and could cause severe burns.

Содержание DDX1230

Страница 1: ......

Страница 2: ...NEMO series battery to battery Charger...

Страница 3: ...NEMO series battery to battery Charger CAUTION THE NEMO MUST BE ISOLATED BEFORE SERVICING MADE IN CHINA...

Страница 4: ...of such information TBB offers standard warranty with its products taking no responsibility for direct or indirect loss due to equipment failure About this Manual This manual describes our product fe...

Страница 5: ...ucture 4 3 1 Terminal and panel definition 4 3 2 Structure dimension 6 4 Preparation and Configuration 7 4 1 Material list 7 4 2 Location 7 4 3 Battery type setting 7 4 4 Wiring and Fuse recommendatio...

Страница 6: ...all cables that are selected meet the wiring recommendations as per table 4 3 and table 4 4 Ensure a good electrical connection Smaller diameter and broken or poor quality cable should not be used It...

Страница 7: ...algorithm for various battery chemicals including LFP Built in automatic temperature and voltage compensated battery charging Support auxiliary battery AGM GEL and WET low voltage under 2V detect bef...

Страница 8: ...2 3 Model Information Figure 2 2 Ordering information scheme Table 2 1 Model series Model Alternator charger PV charger RS485 DX1215 DX1230 DX2415 DX2415L DDX1230 DDX2415 DDX2415L IDX1215 IDX1230 IDX2...

Страница 9: ...ask your dealer for more information and refer to Figure 5 3 on page 12 The panel and terminal definition are as follow Figure 3 1 Charger model and cable for DX DDX model Table 3 1 Connectors or Term...

Страница 10: ...or IN Starter Battery 2 PV PV IN only available for DDX and IDDX 3 OUT Aux battery 4 NEG Common Negative for PV Alternator Starter battery Aux battery 5 Dip switch Battery type setting 6 IGN Ignition...

Страница 11: ...NEMO series battery to battery Charger 6 3 2 Structure dimension Figure 3 3 Structure dimension of the charger...

Страница 12: ...ion RS485 model dependent for IDX and IDDX 4 2 Location Please install the equipment in a clean cool location with good ventilation Working temperature 20 60 Storage temperature 40 85 4 3 Battery type...

Страница 13: ...415L IDX2415L IDDX2415L 40A 50A 15A 20A Wiring recommendation Table 4 3 Input wiring recommendation Model Recommended wiring 1m 2m 5m 10m DX1230 DDX1230 IDX1230 IDDX1230 DX2415L DDX2415L IDX2415L IDDX...

Страница 14: ...cure the charger in a solid surface 5 2 Connecting the power cable Please ensure the correct polarity when connecting Reverse polarity will burn the fuse or damage the charger and void warranty When i...

Страница 15: ...arked PV on battery to battery charger and the PV positive cable Ensure the in line fuse is removed prior to connecting the cable and inserted afterwards 5 Connect the ignition wire 6 Connect the batt...

Страница 16: ...It must be connected at the positive of the auxiliary battery Figure 5 2 Connecting diagram of the sensor cable For IDX and IDDX models RS485 cable can be connected to a PC monitor or a controller to...

Страница 17: ...arger model Polarity of cable connection is correct Voltage sensor is installed on the positive terminal of battery Ignition wire is connected for Euro 6 vehicles 6 2 LED Description 6 2 1 For DX and...

Страница 18: ...good and synchronized with PV charging Quick Flashing Alternator input is overvoltage CHG green Flashing Nemo is charging the battery Solid ON Battery is charged OFF No charging Fault red Flashing Bat...

Страница 19: ...stage Only DDX and IDDX series PV charging is at absorption stage No Alt connected PV charging is at floating stage No Alt connected Both PV and Alt are connected Battery is charged by PV at absorptio...

Страница 20: ...dels LED indicator Description All Alternator input over voltage Internal over temperature or LFP battery temperature fault Battery over temperature Battery disconnected or low voltage under 2V Output...

Страница 21: ...and IDDX models 12V ALT 12 to 25VDC 24V ALT 24 to 50VDC Output nominal voltage 12 24VDC Charge current 12V AUX battery 15A 30A 24V AUX battery 15A Efficiency Max 97 Standby current 5mA Communication I...

Страница 22: ...NEMO series battery to battery Charger 19...

Отзывы: