TO THE INSTALLER
1-3
Models RD30/RC25
To the Installer
1
Beater Rotation
NOTICE!
Beater rotation must be clockwise as
viewed looking into the freezing cylinder.
To correct the rotation on a three-phase machine,
interchange any two incoming power supply lines at the
freezer main terminal block only. To correct rotation on a
single-phase machine, exchange leads inside the beater
motor. (Follow the diagram printed on the motor.)
Electrical connections are made directly to the terminal
block provided in the main control box located behind the
service panel.
It is recommended that beater rotation adjustment be
performed by a Taylor service technician.
Refrigerant
CAUTION!
This machine contains fluorinated
greenhouse gases (F-Gas) to provide refrigeration using
a hermetically sealed circuit or within foam insulation.
This machine’s type of gas, quantity, Global Warming
Potential (GWP), and CO
2
tonnes equivalent information
is recorded on the machine’s data label. The refrigerant
used is generally considered nontoxic and
nonflammable. However any gas under pressure is
potentially hazardous and must be handled with caution.
NEVER
fill any refrigerant cylinder completely with liquid.
Filling the cylinder approximately 80% will allow for
normal expansion.
CAUTION!
Use only approved refrigerant
listed on the machine's data label or authorized through a
manufacturer's technical bulletin. The use of any other
refrigerant may expose users and operators to
unexpected safety hazards.
WARNING!
Refrigerant liquid sprayed onto the
skin may cause serious damage to tissue. Keep eyes
and skin protected. If refrigerant burns should occur,
flush the area immediately with cold water. If burns are
severe, apply ice packs and contact a physician
immediately.
NOTICE!
Taylor reminds technicians to be
aware of and in compliance with local government laws
regarding refrigerant recovery, recycling, and reclaiming
systems. For information regarding applicable local laws,
please contact your local authorized Taylor distributor.
IMPORTANT!
Refrigerants and their
associated lubricants may be extremely moisture
absorbent. When opening a refrigeration system, the
maximum time the system is open must not exceed 15
minutes. Cap all open tubing to prevent humid air or
water from being absorbed by the oil.
Refrigeration Charging and Line
Construction
The dispensing machine is shipped with a refrigerant
holding charge that is sufficient enough to prevent
moisture contamination (8 oz. [227 g] R404A). This
holding charge will become part of the total system
charge.
The condensing unit is shipped with the total amount of
refrigerant required for a typical installation of 75 ft.
(22.86 m) or less with a single dispenser.
Содержание RD30
Страница 16: ...5 2 USER INTERFACE Models RD30 RC25 User Interface 5 Notes...
Страница 26: ...6 10 OPERATING PROCEDURES Models RD30 RC25 Operating Procedures 6 Notes...
Страница 32: ...9 2 PARTS REPLACEMENT SCHEDULE Models RD30 RC25 Parts Replacement Schedule 9 Notes...
Страница 38: ...11 4 LIMITED WARRANTY ON PARTS Models RD30 RC25 Limited Warranty on Parts 11 Notes...