V
-
1C
13
SETTING UP AND WELDING
By rotating the control knob, select either:
-
>
Change
or
Change
Load
-
>
Load
And press the control knob to confirm selection.
Selecting
Change
will take you through the following series of manual weld parameter
setting screens:
CURRENT
TIME
GAS
SAVE
Beginning with
CURRENT
. Set the desired parameter value by turning the control knob then
press the control knob to lock
-
in the parameter and move to the next screens (
TIME, GAS
).
Repeat these steps to adjust and lock
-
in the
TIME
and
GAS
parameters. The final screen
SAVE
, invites you to save the parameters you have set into one of the 20 available memory
locations in the controller. Select the location (
1
-
20
) by turning the control knob and
finalise the save by pressing the control knob which will return you to the normal operating
mode screen, which will now display the parameters you have set.
If you have already saved parameters in one or more of the
memory locations, you may wish to select
Load
at the selection
screen (see above). You can then select (by turning the control
knob) which of the 20 memory locations you wish to load from
and select this parameter set by pressing the control knob. This
will load the parameters from the selected memory location
and return you to the normal operating screen, displaying the
loaded parameters.