OPERATING PROCEDURES
6-9
Model 336, 338, 339
Operating Procedures
6
Draining Product from the Freezing
Cylinder
1. Press the AUTO button, canceling compressor and
beater motor operation.
Press the MIX button, canceling the mix hopper
refrigeration system.
2. Remove the hopper cover, hopper gasket, and air
tube. Take these parts to the sink for cleaning.
3.
If local health codes permit the use of rerun
, place
a sanitized, NSF-approved stainless steel rerun
container beneath the door spout. Press the WASH
button and lower the draw handle. Drain the
remaining product from the freezing cylinder and mix
hopper. When the flow of product stops, press the
WASH button and raise the draw handle. Place the
sanitized lid on the rerun container and place it in the
walk-in cooler.
Note: If local health codes do not permit the use
of rerun, the product must be discarded. Drain the
product into a pail and properly discard it.
4. Repeat step 1 through step 3 for the other side of the
freezer.
Note: For Model 336, both sides must be in Wash
mode. If one side is in Auto mode and the other is in
Wash mode, the side that is in Wash mode will con-
tinue to freeze.
Rinsing
1. Pour 2 gal. (7.6 L) of
cool
clean water into the mix
hopper. With the brushes provided, scrub the mix
hopper, mix inlet hole, and mix level sensing probe.
2. With a pail beneath the door spout, raise the prime
plug and press the WASH button.
3. When a steady stream of rinse water is flowing from
the prime plug opening in the bottom of the freezer
door, lower the draw handle. Drain all the rinse water
from the freezing cylinder, raise the draw handle, and
press the WASH button, canceling the Wash mode.
4. Repeat step 1 through step 3 for the other side of the
freezer.
Cleaning
1. Prepare a pail of approved 100 PPM cleaning
solution (examples: 2-1/2 gal. [9.5 L] of Kay-5
®
or 2
gal. [7.6 L] of Stera-Sheen
®
).
Use warm water and
follow the manufacturer's specifications.
2. Push down the prime plug. Pour the cleaning solution
into the mix hopper.
3. While the solution is flowing into the freezing cylinder,
brush clean the mix hopper, mix level sensing probe,
and mix inlet hole.
4. Press the WASH button to cause the cleaning
solution in the freezing cylinder to agitate.
5. Place an empty pail beneath the door spout and raise
the prime plug.
6. When a steady stream of cleaning solution is flowing
from the prime plug opening in the bottom of the
freezer door, lower the draw handle. Draw off all of
the solution.
7. Once the cleaner stops flowing from the door spout,
raise the draw handle and press the WASH button,
canceling the Wash mode.
8. Repeat step 1 through step 7 for the other side of the
freezer.
Disassembly
BE SURE THE POWER SWITCH IS IN THE
“OFF” POSITION. MAKE SURE NO LIGHTS ARE LIT
ON THE CONTROL PANEL.
1. Remove the handscrews, freezer door, beaters,
scraper blades, and drive shafts from the freezing
cylinders. Take these parts to the sink for cleaning.
2. Remove the front drip tray and the splash shield.
!
ALWAYS FOLLOW LOCAL HEALTH CODES.
!
Содержание Freezemaster 336
Страница 8: ...1 4 TO THE INSTALLER Model 336 338 339 To the Installer 1 Notes...
Страница 18: ...4 6 OPERATOR PARTS IDENTIFICATION Model 336 338 339 Operator Parts Identification 4 Notes...
Страница 22: ...5 4 USER INTERFACE Model 336 338 339 User Interface 5 Notes...
Страница 38: ...9 2 PARTS REPLACEMENT SCHEDULE Model 336 338 339 Parts Replacement Schedule 9 Notes...
Страница 42: ...10 4 LIMITED WARRANTY ON EQUIPMENT Model 336 338 339 Limited Warranty on Equipment 10 Notes...
Страница 46: ...11 4 LIMITED WARRANTY ON PARTS Model 336 338 339 Limited Warranty on Parts 11 Notes...