14
Models 336, 338 & 339
Important: To the Operator
091030
Reset Button
The reset button is located in the service panel. The
reset protects the beater motor from an overload
condition. If an overload occurs, the reset mechanism
will trip. To properly reset the freezer, press the
“AUTO” button to cancel the cycle. Place the power
switch to the “OFF” position. Press the reset button
firmly.
Note:
Do not use metal objects to press the
reset button. Failure to follow this instruction may
result in electrocution.
Turn the power switch to the “ON” position. Press the
“WASH”
button
and
observe
the
freezer’s
performance. Open the side access panel. Make sure
the beater motor is turning the drive shaft in a
clockwise direction (from the operator end) without
binding.
If the beater motor is turning properly, press the
“WASH” button to cancel the cycle. Press the “AUTO”
button (on both sides of the unit) to resume normal
operation. If the freezer shuts down again, contact a
service technician
Air Tube
The air tube serves two purposes. One end of the tube
has a hole and the other end does not.
Figure 6
1. After priming the machine, lubricate the o--rings
on the air tube (
the end with the hole
) and
place it into the mix inlet hole. Every time the
draw handle is raised, new mix and air from the
hopper will flow down into the freezing cylinder.
This will keep the freezing cylinder properly
loaded and will maintain overrun.
2. During long “No Sale” periods, remove the air
orifice. Lubricate the o--rings on the air tube
(
the end without the hole
), and place it into
the mix inlet hole. This will prevent any mix
from entering the freezing cylinder.
The air orifice is used to meter a certain amount
of air into the freezing cylinder. The air orifice
maintains overrun and allows enough mix to enter
the freezing cylinder after a draw.
Adjustable Draw Handle
These units feature an adjustable draw handle to
provide the best portion control. The draw handle
should be adjusted to provide a flow rate of 5 to 7--1/2
oz. of product per 10 seconds. To INCREASE the flow
rate, turn the screw COUNTERCLOCKWISE. Turn
the screw CLOCKWISE to DECREASE the flow rate.
During “Sanitizing” and “Rinsing”, the flow rate can be
increased by removing the pivot pin and placing the
restrictive bar on the TOP. When drawing product,
always
place the restrictive bar on the bottom.
IMPORTANT! When dispensing product, pull only
one draw handle at a time.
Figure 7
Содержание Freezemaster 300 Series
Страница 1: ...Models 336 338 339 Freezemaster 300 Series Operating Instructions 036029 M 4 16 09...
Страница 45: ...Model 336 038333 Rev 4 09...
Страница 46: ...Model 336 038333 33 Rev 4 09...
Страница 47: ...Model 336 038333 62 Rev 4 09...
Страница 48: ...Model 338 051624 27 Rev 4 09...
Страница 49: ...Model 338 051624 33 Rev 4 09...
Страница 50: ...Model 339 046585 27 Rev 4 09...
Страница 51: ...Model 339 046585 33 Rev 4 09...
Страница 52: ...Model 339 046585 62 Rev 4 09...