6-12
OPERATING PROCEDURES
Model C302 NPR
Operating Procedures
6
3.
Pressing the menu (SEL) key will give you the option
for rinsing the left freezing cylinder. Move the cursor
under the word YES. Pressing the menu (SEL) key at
this time will start the beater motor and deliver water
and CO
2
to the left cylinder.
4.
Allow the rinse water to flow into the cylinder until it is
approximately 2/3 full. With a pail under the door
spout, open the draw valve and drain the rinse water.
Repeat this procedure until the rinse water being
drawn is clear.
5.
Repeat step 3 and step 4 for the right freezing
cylinder.
Note: There is a left and a right freezing cylinder for
each LCD.
6.
When draining is complete, press the OFF (<- -) key.
7.
Repeat step 1 through step 6 for the other side of the
machine.
Cleaning
Note:
The following instructions are for one pair of
freezing cylinders under an LCD.
1.
Prepare a pail of approved 100 PPM cleaning
solution (examples: 2-1/2 gal. [9.5 L] of Kay-5
®
or 2
gal. [7.6 L] of Stera-Sheen
®
). Use warm water and
follow the manufacturer's specifications.
Important! Make sure the cleaner is completely dis-
solved.
2.
Pour the cleaning/sanitizing solution into a clean,
empty pail. Place the syrup line with the old syrup
connector into the pail of cleaner.
3. To place the left freezing cylinder in the Sanitize
mode, press the menu (SEL) key. Move the cursor by
pressing the AUTO (- ->) key until the third line
indicates RINSE / SANITIZE. Press the menu (SEL)
key. Move the cursor under the word SANITIZE.
Pressing the menu (SEL) key will give you the option
to sanitize the left cylinder. Move the cursor under the
word YES. Pressing the menu (SEL) key at this time
will start the flow of cleaner/sanitizer through the
syrup system into the freezing cylinder.
4. Repeat step 1 through step 3 for the right freezing
cylinder.
Note: Both sides of the machine have an LCD for
the two freezing cylinders located directly below it.
There is a left and a right freezing cylinder for each
LCD.
5. Open the prime plugs. Allow each cylinder to fill
approximately 2/3 full. Close each prime plug.
6. Continue filling the freezing cylinders with sanitizing
solution until the solution purges out of each vent and
begins draining into the front drip tray. The vents are
located at the top of each mix tank. Press the OFF
(<- -) key.
RINSE
LEFT
SIDE
YES
NO
- - -
L
E
S
>
-
-
-
-
<
RINSE
RIGHT SIDE
YES
NO
- - -
L
E
S
>
-
-
-
-
<
RINSE / SANITIZE
RINSE
SANITIZE
EXIT
- - - - -
L
E
S
>
-
-
-
-
<
SANITIZE
LEFT
SIDE
YES
NO
- - -
L
E
S
>
-
-
-
-
<
Содержание C302NP
Страница 10: ...1 6 TO THE INSTALLER Model C302 NPR To the Installer 1...
Страница 16: ...3 4 SAFETY Model C302 NPR Safety 3 Notes...
Страница 20: ...4 4 OPERATOR PARTS IDENTIFICATION Model C302 NPR Operator Parts Identification 4 Notes...
Страница 44: ...7 2 OPERATOR CHECKLIST Model C302 NPR Operator Checklist 7 Notes...
Страница 48: ...9 2 PARTS REPLACEMENT SCHEDULE Model C302 NPR Parts Replacement Schedule 9 Notes...
Страница 54: ...11 4 LIMITED WARRANTY ON PARTS Model C302 NPR Limited Warranty on Parts 11 Notes...