background image

1-2  

TO THE INSTALLER

Models C001 and C002 

To the Installer 

Air-Cooled Machines

Do not

 obstruct air intake and discharge openings.

Air-cooled machines require a minimum of 3 in. (76 mm) 
of clearance around 

all

 sides of the freezer. Install the 

deflector provided to prevent recirculation of warm air. 
Failure to allow adequate clearance can reduce the 
refrigeration capacity of the freezer and possibly cause 
permanent damage to the compressors.

Water Connections

(Water-Cooled Machines Only) 

An adequate cold water supply must be provided with a 
hand shut-off valve. On the underside rear of the base 
pan, two 1/2 in. (13 mm) I.P.S. water connections for inlet 
and outlet have been provided for easy hook-up. 

Permanently connect the machine using 1/2 in. 

(12.7 mm) inside diameter water lines. (Flexible lines are 
recommended, if local codes permit.) Depending on local 
water conditions, it may be advisable to install a water 
strainer to prevent foreign substances from clogging the 
automatic water valve. There will be only one water-in 
and one water-out connection. 

Do not

 install a hand 

shut-off valve on the water-out line. Water should always 
flow in this order: first, through the automatic water valve; 
second, through the condenser; and third, through the 
outlet fitting to an

 open trap drain.

IMPORTANT! 

A backflow prevention device is 

required on the incoming water connection side. Please 
see the applicable national, state, and local codes for 
determining the proper configuration. Water pressure to 
the unit must not exceed 150 psi (1034 kPa).

Electrical Connections

IMPORTANT! 

In the United States, this 

machine is intended to be installed in accordance with 
the National Electrical Code (NEC), ANSI/NFPA 701987. 
The purpose of the NEC code is the practical 
safeguarding of persons and property from hazards 
arising from the use of electricity. This code contains 
provisions considered necessary for safety.

In all other areas of the world, the machine should be 
installed in accordance with the existing local codes. 
Please contact your local authorities if you have any 
questions.

Each machine requires one power supply for each data 
label on the machine. Check the data label(s) on the 
machine for branch circuit overcurrent protection or fuse, 
circuit ampacity, and other electrical specifications.

See the wiring diagram provided inside the electrical box 
for proper power connections.

WARNING! 

This machine must be properly 

grounded! Failure to do so can result in severe personal 
injury from electrical shock!

IMPORTANT! 

This machine is provided with 

an equipotential grounding lug that is to be properly 
attached to the rear of the frame by the authorized 
installer. The installation location is marked by the 
equipotential bonding symbol (5021 of IEC 60417-1) on 
the removable panel and the frame.

!

FOLLOW YOUR LOCAL ELECTRICAL CODES.

Содержание C001

Страница 1: ...OPERATOR S MANUAL Model C001 and C002 Custard Freezers 5 28 08 Original Publication Updated 8 18 2020 Original Operating Instructions 055073 M...

Страница 2: ..._____________ Electrical Specs Voltage__________________ Cycle____________________ Phase____________________________________________ Maximum Fuse Size _________________________________________________...

Страница 3: ...Assembly 4 5 Accessories 4 6 Section 5 User Interface C001 5 1 C002 5 2 Symbol Definitions 5 3 Section 6 Operating Procedures Assembly 6 1 Sanitizing 6 4 Priming for Continuous Run 6 4 Stopping a Cont...

Страница 4: ...ii 055073 M Section 8 Troubleshooting Guide Section 9 Parts Replacement Schedule Section 10 Limited Warranty on Machines Section 11 Limited Warranty on Parts...

Страница 5: ...e to follow this instruction may result in personal injury or death from electrical shock or hazardous moving parts as well as poor performance or damage to the machine WARNING This machine has many s...

Страница 6: ...ention device is required on the incoming water connection side Please see the applicable national state and local codes for determining the proper configuration Water pressure to the unit must not ex...

Страница 7: ...from abrasion If the supply cord is damaged it must be replaced by the manufacturer service agent or a similarly qualified person to avoid a hazard Secure supply cord ground lead to machine in a locat...

Страница 8: ...e area immediately with cold water If burns are severe apply ice packs and contact a physician immediately NOTICE Taylor reminds technicians to be aware of and in compliance with local government laws...

Страница 9: ...ur Taylor warranty is valid only if the parts are authorized Taylor parts purchased from the local authorized Taylor distributor and only if all required service work is provided by an authorized Tayl...

Страница 10: ...is fact known to any technician he she employs It should also be noted that Taylor does not warrant the refrigerant used in its machines For example if the refrigerant is lost during the course of ord...

Страница 11: ...installer The installation location is marked by the equipotential bonding symbol 5021 of IEC 60417 1 on the removable panel and the frame WARNING This machine must NOT be installed in an area where a...

Страница 12: ...re very sharp and may cause injury CAUTION This machine must be placed on a level surface Failure to comply may result in personal injury or machine damage WARNING Only install this machine in a locat...

Страница 13: ...ection 4 4 1 Models C001 and C002 Operator Parts Identification 4 Operator Parts Identification C001 Exploded View Figure 4 1 1 2 3 4 5 6a 6b 6c 6 8 22 10 21 11 9 12 11 13 14 15 16 17 18 19 20 6e 6d 7...

Страница 14: ...062451 6c Pin Quick Release 3 16 X 1 S 027813 6d Tube Inner Regulator 059787 6e Regulator A Flow Outer 059784 7 Trim Rear Corner L 067971 8 Panel Rear 066551 9 Trim Rear Corner R 067972 10 Filter Air...

Страница 15: ...OPERATOR PARTS IDENTIFICATION 4 3 Models C001 and C002 Operator Parts Identification 4 C002 Exploded View Figure 4 2 1 22 2 3 24 5a 5d 5b 5c 5e 6 4 1 7 8 23 18 9 10 11 12 13 14 15 16 17 21 19 20 5...

Страница 16: ...or 059787 5e RegulatorA Flow Outer 059784 6 Panel Rear 053782 7 Panel Upper Side Right 054449 8 Pan Drip 11 5 8 Long 027503 9 Trim Rear Corner Right 054459 10 Panel A Side Right X66497 11 Nut 10 32 Wh...

Страница 17: ...9 2 Arm Handle 055183 3 Plate Draw 054445 4 O ring 2 3 4 OD X 139W 70 055182 5 Screw Door Stem 055180 6 O ring 563 OD X 070W 013 043758 7 Bearing Front 013116 8 Blade Scraper 054485 Item Description P...

Страница 18: ...riate Taylor approved food safe lubricant 1 2 4 3 5 6 7 8 Item Description Part No 1 Sanitizer Stera Sheen 055492 2 Lubricant Taylor 4 oz 047518 3 Kit A Tune Up X54630 1 4 Pail 10 Qt 013163 Item Descr...

Страница 19: ...001 Figure 5 1 1 2 3 4 5 6 7 8 9 Item Description 1 Light Hopper Refrigeration 2 Switch HOPPER REFRIGERATION ON OFF 3 Light MIX LOW 4 Light Freeze Mode 5 Switch FREEZE CHILL Mode Item Description 6 Li...

Страница 20: ...2 1 2 3 4 5 6 7 8 3 4 5 6 7 8 9 9 Item Description 1 Light Hopper Refrigeration 2 Switch HOPPER REFRIGERATION ON OFF 3 Light MIX LOW 4 Light Freeze Mode 5 Switch FREEZE CHILL Mode Item Description 6...

Страница 21: ...arena the words on many of our operator switches and buttons have symbols to indicate their functions Your Taylor machine is designed with these international symbols The following chart identifies t...

Страница 22: ...5 4 USER INTERFACE Models C001 and C002 User Interface 5 Notes...

Страница 23: ...ing the freezer for the first time or need information to get to this starting point in our instructions turn to page 6 7 Disassembly and start there Assembly WARNING Make sure the power switch is in...

Страница 24: ...d fit snugly but not so tightly that the dasher cannot be turned slightly to engage the driveshaft If the dasher slides in too easily with little or no resistance there will not be enough force agains...

Страница 25: ...zer door Seat the door flush with the freezing cylinder With the door seated on the freezer studs install the stud nuts handscrews The short stud nuts go on the bottom and the long stud nuts go on top...

Страница 26: ...HARGE OPENINGS Failure to do so may result in severe personal injury contaminated product or component damage Repeat these steps for the other side of the freezer Priming for Continuous Run 1 With san...

Страница 27: ...Wait 1 or 2 minutes If the noise continues place the FREEZE CHILL switch in the OFF position until product begins flowing from the door Place the FREEZE CHILL switch back in the FREEZE mode position R...

Страница 28: ...lid on the rerun container and place it in the walk in cooler Note If local health codes do not permit the use of rerun the product must be discarded Follow the instructions in the previous step exce...

Страница 29: ...urn the tool clockwise to lock the tool in the dasher and then pull the dasher out Figure 6 19 Brush Cleaning 1 Prepare a sink with an approved cleaning solution examples Kay 5 or Stera Sheen Use warm...

Страница 30: ...tion Brush clean the mix inlet holes in the mix hoppers Figure 6 22 8 Brush clean the rear shell bearings at the back of the freezing cylinders with the black bristle brush Figure 6 23 9 Thoroughly br...

Страница 31: ...ush to clean the mix inlet hole which extends from the mix hopper down to the rear of the freezing cylinder Use the black bristle brush to thoroughly clean the rear shell bearing at the rear of the fr...

Страница 32: ...er cooled check the water lines for kinks or leaks Kinks can occur when the machine is moved back and forth for cleaning or maintenance Deteriorated or cracked water lines should be replaced only by a...

Страница 33: ...riveshaft seal a Replace worn nicked or missing driveshaft seal 6 1 b Inadequate lubrication b Lubricate properly 6 1 6 Product is not being fed into the freezing cylinder a Inadequate mix in hopper M...

Страница 34: ...ing b Brush clean the rear shell bearing area regularly 6 7 15 Freezing cylinder walls are scored a The dasher assembly is damaged a Replace the dasher assembly 6 1 7 2 b The front bearing is either m...

Страница 35: ...y 6 Months Annually Front Bearing X Inner Flow Regulator O rings X Draw Plate O ring X Freezer Door O ring X Driveshaft Seal X Scraper Blades X Black Bristle Brush 1 x 2 Inspect and replace if necessa...

Страница 36: ...9 2 PARTS REPLACEMENT SCHEDULE Models C001 and C002 Parts Replacement Schedule 9 Notes...

Страница 37: ...TED WARRANTY CONDITIONS 1 If the date of original installation of the Product cannot be verified then the limited warranty period begins ninety 90 days from the date of Product manufacture as indicate...

Страница 38: ...epairs due to theft vandalism wind rain flood high water water lightning earthquake or any other natural disaster fire corrosive environments insect or rodent infestation or other casualty accident or...

Страница 39: ...IAL OR INCIDENTAL DAMAGES INCLUDING CLAIMS FOR LOST SALES LOST PROFITS PRODUCT LOSS PROPERTY DAMAGES OR SERVICE EXPENSES ARE EXPRESSLY EXCLUDED THE EXPRESS WARRANTIES MADE IN THIS LIMITED WARRANTY MAY...

Страница 40: ...10 4 LIMITED WARRANTY ON MACHINES Models C001 and C002 Limited Warranty on Machines 10 Notes...

Страница 41: ...verified proof of purchase may be required at time of service 2 This limited warranty is valid only if the Part is installed and all required service work in connection with the Part is performed by a...

Страница 42: ...warranty service work promptly upon arrival 9 Failure damage or repairs due to faulty installation misapplication abuse no or improper servicing unauthorized alteration or improper operation or use as...

Страница 43: ...OR INCIDENTAL DAMAGES INCLUDING CLAIMS FOR LOST SALES LOST PROFITS PRODUCT LOSS PROPERTY DAMAGES OR SERVICE EXPENSES ARE EXPRESSLY EXCLUDED THE EXPRESS WARRANTIES MADE IN THIS LIMITED WARRANTY MAY NO...

Страница 44: ...11 4 LIMITED WARRANTY ON PARTS Models C001 and C002 Limited Warranty on Parts 11 Notes...