Important: Operator Checklist
j
6. If your unit is air cooled, check the
condensers for an accumulation of dirt and
lint. Dirty condensers will reduce the efficiency
and capacity of the unit. Condensers should
be cleaned at least once a month with a soft
brush.
Never use screwdrivers or other
metal probes to clean between the
condenser fins.
Failure to follow this
instruction may result in electrocution.
Note:
For units equipped with an air filter, it
will be necessary to vacuum the filters clean
at least once a month.
Caution: Always disconnect
electrical power prior to cleaning the
condenser.
Failure to follow this instruction
may result in electrocution.
j
7. If your unit is equipped with an auxiliary
refrigeration system, check the auxiliary
condenser for accumulation of dirt and lint.
Dirty condensers will reduce the refrigeration
capacity of the mix hopper. Condensers must
be cleaned monthly with a soft brush.
Never
use screwdrivers or other metal probes to
clean between the fins.
Failure to follow this
instruction may result in electrocution.
Caution: Always disconnect
electrical power prior to cleaning the
condenser.
Failure to follow this instruction
may result in electrocution.
j
8. If your unit is water cooled, check the water
lines for kinks or leaks. Kinks can occur when
the unit is moved back and forth for cleaning
or maintenance purposes. Deteriorated or
cracked water lines should be replaced only
by an authorized Taylor service technician.
Winter Storage
If the place of business is to be closed during the
winter months or for any extended period of time, it
is important to protect the unit by taking certain
precautions, particularly if the building is to be left
unheated and subject to freezing conditions.
Disconnect the unit from the main power source to
prevent possible electrical damage.
On water cooled units, disconnect the water supply.
Relieve pressure on the spring in the water valve.
Use air pressure on the outlet side to blow out any
water remaining in the condenser.
This is
extremely important.
Failure to follow this
procedure may cause severe and costly damage to
the refrigeration system.
Your local authorized Taylor distributor can perform
this service for you.
Wrap detachable parts of the unit with plastic wrap
or shrink wrap, including, but not limited to, the
beater, blades, drive shaft, and freezer door. Place
those parts in a protected, dry place. Rubber trim
parts and gaskets can be protected by wrapping with
moisture-proof paper. Before such storage, all parts
should be thoroughly cleaned of dried mix or
lubrication accumulations which attract mice and
other vermin.