background image

17

History record mode

In normal display mode, press

 [SET/HISTORY]

 to enter the history 

record mode. In this mode, users can check the history data records 
in past 20 hours, press 

[+]

 to view next history data record, press 

[-]

 to 

view previous history data record. In normal display mode, press 

[MODE]

 key and

 [SET/HISTORY]

 key together for 3 seconds to enter 

the factory regulation mode. In factory regulation mode, the 
accuracy of indoor/outdoor temperature, indoor/outdoor humidity 
and atmospheric pressure sensors can be adjusted.

Troubleshooting

FCC Info

If the Receiver does not receive a transmission from a remote unit 
channel for 10 minutes, the wind speed, outdoor temperature and 
humidity will show dashes. To correct this problem:

1.

 Go to the remote location of that channel to check that the unit is 

properly positioned, within the appropriate transmission range.

2.

 If new batteries are faulty on the initial installation, install fresh 

batteries. If you did not notice the Low Battery icon warning and 
the product performed correctly after initial set up, the batteries 
have lost their charge. Replace the batteries.

3. 

Check to make sure the transmission path is clear of obstacles and 
interference.

Caution: 

Changes or modifications not expressly approved by the party 

responsible for compliance could void the user's authority to operate the 
equipment.

Note: 

This device complies with part 15 of the FCC Rules. Operation is subject to 

the following two conditions: (1) this device may not cause harmful 
interference, and (2) this device must accept any interference received, 
including interference that may cause undesired operation. This equipment has 
been tested and found to comply with the limits for a Class B digital device, 
pursuant to part 15 of the FCC rules. These limits are designed to provide 
reasonable protection against harmful interference in a residential installation. 
This equipment generates, uses and can radiate radio frequency energy and, if 
not installed and used in accordance with the instructions, may cause harmful 
interference to radio communications. However, there is no guarantee that 
interference will not occur in a particular installation. If this equipment does 
cause harmful interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is encouraged to try 
to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which 

the receiver is connected.

- Consult the dealer or an experienced radio/TV technician for help.

FCC Code:

 RMW-2752N

Содержание 2752N

Страница 1: ...Instruction Manual Digital Wireless Weather Station with Dual Mount Wind Sensor Leading the Way in Accuracy 2752N...

Страница 2: ...ore use and keep it handy for future reference Items included in this package shown on page 3 1 Base Station an indoor unit which displays temperature and other readings 2 Wind Gauge Remote Sensor an...

Страница 3: ...3 Description of Parts mounting bracket Remote Wind Gauge Sensor Unit Base Receiver Unit Line 1 Line 3 Line 2 1 Line 4 9 10 8 Wind Sensor Cups Compass Wind vane...

Страница 4: ...o select F or C temperature scale 8 Battery Compartments On back of Receiver Unit and on top of Wind Gauge Sensor base The Home Receiver unit uses 2 AAA batteries and Wind Gauge Remote Sensor uses 2AA...

Страница 5: ...Time Alarm Current temperature base sensor location Current humidity base sensor location Current temperature remote sensor location Current humidity remote sensor location Current day Current date Cu...

Страница 6: ...me Unit Receiver Batteries Important Install the receiver s batteries first before installing batteries in the Wind Gauge Remote Sensor 1 Remove the battery compartment cover located on the back of th...

Страница 7: ...onnect the wind base and top of housing and fasten with an M3x22 screw with nut included 5 Remove battery compartment cover on the remote sensor and insert 2 AA batteries Replace battery compartment c...

Страница 8: ...Note The effective range is vastly affected by the building materials and where the receiver and remote units are positioned Try various set ups for the best results Shorten the distance between recei...

Страница 9: ...following picture The Wind Gauge Remote Sensor features five buttons MODE NEXT SET HISTORY There are 8 modes including Normal Mode Clock Mode Date Mode Indoor Temperature Mode Indoor Humidity mode Out...

Страница 10: ...etting Users can adjust the hour of current time in clock mode Press to increase hour press to decrease hour press for increase hour rapidly press to decrease hour rapidly Minute setting Users can adj...

Страница 11: ...decrease the indoor low temperature alarm value press to increase the indoor low temperature alarm value rapidly press for to decrease the indoor low temperature alarm value rapidly Maximum value of i...

Страница 12: ...re alarm rapidly press to decrease the outdoor high temperature alarm value Outdoor low temperature alarm setting Users can adjust the outdoor low temperature alarm setting in this mode Press SET HIST...

Страница 13: ...e wind speed Press NEXT to change the parameters setting mode 5 High wind speed alarm setting Users can adjust high wind speed alarm setting in this mode press SET HISTORY to allow or forbid high wind...

Страница 14: ...tdoor low humidity alarm value press to decrease the outdoor low humidity alarm value press to increase the outdoor low humidity alarm value rapidly press to decrease the outdoor low humidity alarm va...

Страница 15: ...low humidity alarm value press to decrease the indoor low humidity alarm value press to increase the indoor low humidity alarm value rapidly press to decrease the indoor low humidity alarm value Maxi...

Страница 16: ...diagram shows the order of date display format Year setting Users can adjust the year setting in this mode press to increase the year setting press to decrease the year setting Press to increase year...

Страница 17: ...y the party responsible for compliance could void the user s authority to operate the equipment Note This device complies with part 15 of the FCC Rules Operation is subject to the following two condit...

Страница 18: ...to extremely severe temperatures 7 Do not clean either unit with abrasive or corrosive materials This may scratch plastic parts and corrode electronic circuits 8 Do not subject either unit to excessiv...

Страница 19: ...from 12 to 12 user setting Daylight saving time is adjusted automatically The daylight saving time is adjusted on the basis of different time zone The date display format can be set as YYYY MM DD MM D...

Страница 20: ...plaining reason for return to Taylor Precision Products Inc 2220 Entrada Del Sol Suite A Las Cruces New Mexico 88001 Customer Service Phone 1 800 225 4834 Customer Service Fax 1 575 526 4347 There are...

Страница 21: ...digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses...

Отзывы: