Taylex
®
ABS Home Owner
’
s Manual
Page. 15
2. General
The Taylex
®
ECO Controller Assembly (complete with Controller, Control Panel Box, 3 x
GPO Assembly and Blower Box) is classed as electrical equipment and has been certified
to comply with AS/NZS3820 and AS/NZS 3100:2017, meeting the Electrical Safety
requirements in Australia and New Zealand.
Your Taylex
®
ABS is designed to operate automatically and its operation will usually be event
free. The Eco Control Panel provides visual and audible indictors of both normal operating
conditions and fault conditions. The illustration on the previous page provides description
markers that correspond with the following description of their operation.
A.
VISUAL ALARM / DISPLAY.
This is a LED display that describes normal and
abnormal conditions by using a number of flashes. See later in this document to
understand their meaning. This is also your visual alarm.
B.
MUTE ALARM.
This is a “soft touch’ key that when pressed, silences the audible
alarm for a period of 24 hours.
Note:
THE POWER SUPPLY
The power outlets for the ECO Controller for your system are located inside the Blower
Box.
Normal Operation Circuit Breaker Activated
Each switch
must be in the ON position at all times
. If any or all switches are OFF, the
treatment process and alarms may not function.
The single GPO is for the 240V
– 12V power supply for your controller and the double GPO
is for your Pump and Blower. The double GPO contains a 5amp breaker underneath the
GPO, which will activate in the case of a fault with the pump and/or blower. If the breaker
is activated it will trigger the associated alarm on the Controller. You can reset the Breaker
by pushing in the reset button. If the breaker is activated again, please contact your Service
Agent to rectify the issue.