background image

 

2

 

 

 

 
 

 
 

 

 

First Operation 

 

Open the water source and check for leaks.

 

 

Perform 2-3 flushing cycles as outlined below. 

 

Filter is ready for use. 

 

 

Flushing the filter 

 

The disc element needs to be cleaned when the 
head loss across the filter reaches 0.5-0.7 bar and 

the red pin protrude from the pressure indicator. 
picture 6 

 

Open the bottom flush valve 

 picture 7 

 

Turn the handle ¼+ of a turn until the stop 
picture 8 

 

Wait 15

30 seconds. 

 

Turn the filter handle back  

 

Close the bottom flush valve 

 

Open the secondary flush valve for 10 seconds and 

close. 

 

Please note

: the strength required to turn the handle 

may vary according to the water quality and its source.

 

 

Trouble shooting 

 

Head loss is not decreasing after flushing cycle: 

o

 

Check that the pressure is not below 2 
bar. 

o

 

Check that there is no disturbance to the flushing flow. 

o

 

Flush the internal screen by opening its flush valve. 

o

 

Repeat the flushing cycle again, do not forget to open the filter flush valve before turning the 

handle. 

 

Filter is still not clean: 

o

 

Clean the internal screen by disassembling and flushing manually. 

o

 

Open the filter cup. 

o

 

Disassemble the lower thread and remove piston 

o

 

Check that the seal is intact and in its position. 

 

Filter handle is not turning 

o

 

Check that the flush valve is fully open before turning the handle. 

o

 

Check that water flows through the bottom valve. 

o

 

Check that inlet pressure is lower than 6 bars 

 

Filter handle is still not turning 

o

 

Partly Close the inlet maintenance valve and turn the handle 

o

 

Perform a flushing cycle. 

o

 

Open the inlet valve 

 

 

 

 
 

 
 

 

 
 

 
 

 

 

 

 

 
 

Picture 6 

 

Picture 7 

 

 

 Picture 8

 

Picture 9

 

Отзывы: