N
E
SERVICE:
Make sure that the appliance is serviced only
by specialist personnel, and that only original
spare parts or accessories are used to replace
existing parts/accessories.
Any misuse or failure to follow the instructions
for use renders the guarantee and the
manufacturer's liability null and void.
DESCRIPTION
A
Switches
B
One-way valve
C
Aluminium filter/s
D
Lights
E
Chimney
INSTALLATION
Be sure to remove all packaging material from
inside the appliance.
Make sure the air vented is not sent through
the ducts used to vent fumes from other gas or
fuel appliances.
Specific air venting regulations applicable must
be complied with when installing the appliance.
Respect the legal provisions concerning safety
distances from other elements such as pipes,
electrical connections, etc.
The minimum distance between the support
surface of the cooking elements and the lower
part of the appliance is 65-75cm. (This distance
can be greater if specified in the cooking
elements’ installation instructions).
Do not cover or obstruct any of the openings of
the appliance.
The plug must be easily accessible so it can be
disconnected in an emergency.
Do not add new sections to the extraction tube
provided, as it could cause the appliance to
malfunction.
Make sure you have the necessary elements
for the installation before you start:
•
Impact drill
•
8 mm drill bit
•
Philips screwdriver
ELEMENTS CONTAINED IN THE BOX FOR
INSTALLATION (FIG.1):
1. 4X30 mm screws (9 pcs.)
2. 3X10 mm screws (2 pcs.)
3. Screw plug (9 pcs.)
4. Wall bracket
5. Chimney hangers (2 pcs.) (small and large)
6. Lower chimney
7. Upper chimney
8. One-way valves (2 pcs.)
9. Exhaust pipe
ASSEMBLAGE
If you have an outlet to the outside, your hood
can be connected as shown in the image below
by means of an exhaust pipe (with an internal
diameter of 150 mm).
NOTE:
Before installation, turn the unit off and
unplug it from the power outlet.
Before installation, you must remove the
grease filters as shown below, you must press
the lock and pull down:
INSTALLATION FOR EXTERIOR
VENTILATION:
1. Place the wall bracket on the wall and mark
the 3 points where the screws should be fixed.
(As a reference, take the measurements of
Fig.2).
2. Drill 3 holes of 8 mm and insert 3 screw
plugs there.
3. Replace the wall bracket and fix it to the wall
with the 4X30 mm screws.
Содержание T60IXAL
Страница 3: ...E A D C B T60IXAL x2 T70IXAL x2 T90IXAL x3 ...
Страница 53: ......
Страница 54: ......