Taurus MMA-400 Скачать руководство пользователя страница 7

 

-

 6 

possible and the following procedures are suggested:

 

1

 

Welders and cutters with cardiac pacemaker implants should obtain medical 

advice on the effects of EMF on the implant.

 

2

 

Welders should minimise the possibility of electromagnetic field damage 

through the following methods.

 

2.1

 

Route the electrode and ground cables together and, where possible, secure 

them with tape.

 

2.2

 

Do not wrap wires and cables around arms or coil power cables around body 

parts. If possible, keep cables away from the body.

 

2.3

 

Keep the distance between the ground clamp to the workpiece and the 

electrode as short as possible.

 

2.4

 

Keep a safe distance between the operator and the welding/cutting machine.

 

Protection from Fumes and Gases

 

 

Welding and cutting produces a lot of fumes and gas, which is 

harmful to human health.

 

1

 

The working area should be well ventilated and welding/cutting activities 

should not be executed in confined spaces. Eye, nose or throat discomfort 

can be the result of inadequate ventilation.

 

2

 

Welding and cutting in or near locations where chlorinated hydrocarbon 

vapours are produced such as degreasing, cleaning and spraying 

operations, should not be undertaken since phosgene, a highly toxic gas as 

well as other irritants can be reaction products.

 

3

 

The industry offers a variety of respiratory masks and must be used in 

conditions where clean breathing air is required.

 

Gas Cylinder Safety

 

 

Gas leaks can occur on cylinders connected to welding/cutting 

operations if the system is not properly managed and maintained.   

A ruptured cylinder or relief valve can cause serious injury or can 

even be fatal.

 

 

 

Содержание MMA-400

Страница 1: ...1 Inverter DC Manual Metal Arc Welding Machine MODELS MMA 400 MMA 400L PRO MMA 630 MMA 630L PRO Operation Manual Read this manual carefully before installing operating and maintaining the machine...

Страница 2: ...may be printed in this operation manual This manual will contain as far as possible preventive and safe operation measures related to the equipment but cannot exclude the occurrence of accidents There...

Страница 3: ...s 3 Warnings 4 Packaging and Transportation 7 Parameters 8 Product Description 8 Working Principle 11 Installation and Wiring 12 Brief Procedure for Welding Operation 14 Maintenance 15 Common Machine...

Страница 4: ...the following safety precautions must be followed 1 The operator must be suitably qualified and certificated before operating the equipment 2 A qualified professional should be employed to ensure that...

Страница 5: ...kin damage Avoid clothes with front pockets and button up sleeves and collars 3 Use appropriate flame retardant shields or curtains to protect bystanders from arc radiation and high temperature sparks...

Страница 6: ...mportant 2 Insulation layers of electric wires and cables must be checked regularly for wear and replaced if necessary 3 All equipment used and clothing worn during the welding cutting operation shoul...

Страница 7: ...mes and Gases Welding and cutting produces a lot of fumes and gas which is harmful to human health 1 The working area should be well ventilated and welding cutting activities should not be executed in...

Страница 8: ...n use If there is no hose connected to the flowmeter then cover the outlet with a dust cap Protection Against Moving and Rotating Parts Moving parts such as fans rotors and belts can be hazardous 1 En...

Страница 9: ...circuit voltage 68V 68V Insulation grade F IP grade IP21S Package dimensions mm 647 367 542 N W kg 18 20 19 21 Model MMA 630 MMA 630L PRO Parameters Value Rated input voltage 3PH AC380V 15 50 60Hz 3PH...

Страница 10: ...try electric power construction shipbuilding machinery manufacturing building construction indoor and outdoor decoration hardware and kitchen equipment production The inverter welding machines in this...

Страница 11: ...e Connects to electrode holder cable set in DC electrode negative mode Connects to earth clamp cable set in DC current electrode positive mode 3 Remote control box aviation socket Connects to remote c...

Страница 12: ...nd program channels are displayed 9 Arc force current adjustment The function of the arc force is to eliminate the phenomenon of electrode sticking and is adjusted by rotating the knob 10 VRD function...

Страница 13: ...e the humidity is as low as possible and the ambient temperature is within the range of 10 C 40 C 1 2 The machine should be installed on a flat preferable level surface but in any case not on a surfac...

Страница 14: ...ust be in compliance with national and local regulations 3 3 Before the connection is carried out the main power supply to the control box must be switched off 3 4 An earth cable set must be securely...

Страница 15: ...ng gloves insulating safety shoes 1 2 Confirm the electrical grid connected to the welding machine is consistent with the correct power supply of the machine 1 3 Confirm that the insulation layers on...

Страница 16: ...o suit the situational demands 1 11 After completion of the operation turn off the power using the switch on the rear panel of the machine 2 Table Guideline for MMA Electrode Specification and Welding...

Страница 17: ...amage to the transformer and semi conductor parts Common Machine Malfunctions and Solutions Warning Machine maintenance and repair must be carried out by qualified technicians The operating voltage in...

Страница 18: ...mediately Power switch broken Replace power switch IGBT damaged Replace IGBT and drive circuit board Bridge rectifier damaged Replace the bridge rectifier Control board damaged Replace control board 3...