20 -
No.
Problem
Root cause
What to do
9
The ''machine
light'' is lit. Digital
display and fan
operational. Error
indicator light off.
High frequency
discharge sound
and no-load
output. No gas
flow.
No air discharge from the
air-inlet hose.
Check the integrity of the air
inlet hose.
Press the torch trigger. If the
solenoid valve does not
respond
and
its
wiring
terminals
are
intact,
the
solenoid valve may be faulty.
Replace the solenoid valve.
If the problem remains after
replacement of the solenoid
valve, the problem lies with
the control circuit.
Replace the control board.
Air and electricity socket hole
is blocked.
Check the air and electricity
socket hole.