11
-
1.3.
The machine should not be operated in a work station exposed to wind.
Should a windy environment be unavoidable, suitable screening should be
installed.
1.4.
In order to allow for efficient ventilation, a clear space of at least 20cm should
be allowed in front of and behind the machine as well as at least 10cm at each
side.
2. Power Input Requirements
The power supply waveform should be the standard sine wave with rated voltage
AC220V±15% 50Hz.
Model
MMA
-
200
Parameters
Value
Power supply
:
1PH
--
AC220V±15% 50/60Hz
Rated input current
:
32.0A
Input cable
:
≥2.5mm
2
Output cable
:
20mm
2
Ground cable
:
≥2.5mm
2
3. Main Power Supply Connection
Pay attention to prevent electric shock
Wear goggles
Take note of the following when the machine is connected to the main power
supply:
3.1.
The connection must be carried out by a qualified electrician or technician.
3.2.
The connection must be in compliance with national and local regulations.
3.3.
Before the connection is carried out, the main power supply to the control box
must be switched off.