3

  

General

 

Characteristics

 

RMM_00053_02 

21 / 38 

VEGA1 Series 

3.6  Conformity – Compliance 

Tattile

 

declares

 

under

 

sole

 

responsibility

 

that

 

the

 

products

 

described

 

in

 

this

 

manual

 

are

 

in

 

conformity

 

with

 

the

 

essential

 

requirements

 

of

 

the

 

following

 

EU

 

directives

 

and

 

standards:

 

Compliance

 

Description

 

 

 

2014/53/EU

RED

 

Directive

 

(

1

)

 

 

2011/65/EU

RoHS

 

Directive

 

 

 

(1)

 

The

 

objectives

 

and

 

protection

 

requirements

 

of

 

the

 

Low

 

Voltage

 

Directive

 

2014/35/EU

 

and

 

EMC

 

Directive

 

2014/30/EU

 

are

 

applied

 

under

 

Directive

 

2014/53/EU,

 

Article

 

3.1.

 

 

 

and

 

that

 

the

 

standards

 

and/or

 

technical

 

specifications

 

reference

 

below

 

have

 

been

 

applied:

 

RED 
Art 3.1a Safety 
specifications

 

 

EN

 

60950

1:2006

 

+A11:2009

 

+A1:2010

 

+A12:2011

 

+AC:2011

 

+A2:2013

 

(Safety

 

IT

 

equipment)

 

 

EN

 

60950

22:2006

 

+A11:2008

  

Safety

 

ITE,

 

part

 

22:

 

Equipment

 

installed

 

outdoors

 

RED 
Art 3.1b EMC 
specifications

 

 

EN

 

301

 

489

1

 

v2.2.0

 

ERM,

 

EMC

 

Common

 

requirement

 

 

EN

 

301

 

489

17

 

v3.2.0

 

ERM,

 

EMC,

 

Specific

 

for

 

Wideband

 

2.4GHz

 

System

 

 

EN

 

301

 

489

19

 

v2.1.1

 

ERM,

 

EMC,

 

Specific

 

for

 

Receive

 

Only

 

Mobile

 

Earth

 

Station

1.5GHz

 

band

 

 

EN

 

50293:2012

 

Road

 

traffic

 

signal

 

system

 

 

EMC

 

 

EN55022,

 

emission

 

class

 

B

 

 

EN61000

4

2,

 

ESD

 

6

 

kV

 

contact

 

/

 

8

 

kV

 

Air

 

 

EN61000

4

3,

 

RF

 

radiated

 

 

20

 

V/m

 

AM

 

1

 

kHz

 

80%

 

(80

1000

 

MHz),

 

 

20

 

V/m

 

AM

 

1kHz

 

80%

 

(1

6

 

GHz)

 

 

10

 

Veff/m

 

PM

 

50%

 

200Hz

 

(900

 

MHz,

 

1890

 

MHz)

 

 

EN61000

4

4,

 

EFT

 

Burst

 

2

 

kV

 

DC

 

power,

 

2

 

kV

 

signal

 

ports

 

 

EN61000

4

5,

 

Surge

 

 

DC

 

power

 

1

 

kV

 

Line

 

to

 

Line,

 

2

 

kV

 

Line

 

to

 

Ground

 

 

Signal

 

ports

 

1

 

kV

 

Line

 

to

 

Line,

 

2

 

kV

 

Line

 

to

 

Ground

 

 

EN61000

4

6,

 

RF

 

conducted

 

20

 

V

 

(0.15

 

÷

 

80

 

MHz)

 

 

EN61000

4

8,

 

Pwr

 

frequency

 

magnetic

 

field

 

100

 

A/m

 

50

 

Hz

 

RED 
Art 3.2 Spectrum 
(Radio spec.)

 

 

EN

 

300

 

328

 

v2.2.2

 

ERM,

 

Spectrum

 

for

 

for

 

Wideband

 

2.4GHz

 

System

 

 

EN

 

303

 

413

 

v1.1.1

 

ERM,

 

Spectrum

 

for

 

Global

 

Navigation

 

Satellite

 

System,

 

1.5GHz

 

bands

 

RoHS 
Art. 4.1 
Prevention 

 

EN

 

50581:2012

 

Technical

 

documentation

 

for

 

the

 

assessment

 

of

 

electrical

 

and

 

electronic

 

products

 

with

 

respect

 

to

 

the

 

restriction

 

of

 

hazardous

 

substances

 

Other

 

standards

 

 

EN

 

62471:2008

 

Photobiological

 

safety

 

of

 

lamps

 

and

 

lamps

 

systems

 

 

F01870:

 

Risk

 

Group

 

1

 

(infrared

 

eye

 

hazard)

 

 

F01872:

 

Exempt

 

Group

 

 

EN

 

62311:2008

 

Limit

 

to

 

EM

 

Field

 

for

 

human

 

exposure

 

 

EN

 

60068

2

1

 

Environmental

 

testing.

 

Cold

 

test

 

(

40°C,

 

16h)

 

 

EN

 

60068

2

2

 

Environmental

 

testing.

 

Dry

 

Heat

 

test

 

(+60°C,

 

16h)

 

 

EN

 

60068

2

30

 

Environmental

 

testing.

 

Damp

 

Heat

 

(+55°C

 

RH

 

95%,

 

2x24h)

 

 

EN

 

60529

 

Degrees

 

of

 

protection

 

provided

 

by

 

enclosures

 

(IP66,

 

IP67)

 

Содержание Vega1 Series

Страница 1: ...Via Gaetano Donizetti 1 25030 Mairano BS Italy Tel 39 030 97000 Fax 39 030 97001 info tattile com VEGA1 Series Automatic Number Plate Reader Original Instructions for Installation Document number RMM_...

Страница 2: ...be reproduced in any form nor information therein contained disclosed to third parties nor methods procedures or tests described performed without the authorization of Tattile S r l All trademarks an...

Страница 3: ...e 14 3 3 1 Product Overview 14 3 3 2 Power Supply Signal and I O Connector 15 3 3 3 Gigabit Ethernet Connector 17 3 4 Technical Sheet Specifications 18 3 5 Identification of the Product 20 3 6 Conform...

Страница 4: ...ating the Firmware 33 6 Troubleshooting and Support 34 6 1 Troubleshooting 34 6 2 Support 34 7 Maintenance 35 7 1 Cable Check 35 7 2 Cleaning the Protection Glass 35 7 3 Fastening System Check 35 7 4...

Страница 5: ...section 17 Figure 9 Gigabit Ethernet connector 17 Figure 10 Product label 20 Figure 11 Scheme of Assembly Instructions 24 Figure 12 Cable and Conductor insulation removing 24 Figure 13 Correct Backshe...

Страница 6: ...or IT administrator responsible for product integration configuration and software development Supply all information on Product characteristics Product usage Table 1 Who this document is for 1 3 Typo...

Страница 7: ...Possible consequences optional Preventive measure NOTICE Type and source of danger used to address practices not related to physical injury Possible consequences optional Preventive measure Useful sug...

Страница 8: ...ctrical connections Making or breaking connections when power is on can results in damage to the device Do not place the power supply and signal cables parallel to cables carrying high current switchi...

Страница 9: ...ngth 860 nm 15 nm spectral bandwidth 50 of max intensity Hazard Ultraviolet hazard 200 400 nm Es Euva Retinal blue light hazard 300 400 nm Lb Retinal blue light or thermal hazard 400 780 nm Lr Cornea...

Страница 10: ...ic number plate recognition for the following applications Single lane road tracking Surveillance and access control Congestion charge Limited traffic areas priority lanes Traffic monitoring Logistic...

Страница 11: ...y lanes Its high sensitivity image sensors are available for ANPR reading video streaming even in extreme and low light conditions The camera allows an easy setup to minimize the installation and main...

Страница 12: ...ral Characteristics RMM_00053_02 12 38 VEGA1 Series 3 2 Dimensions 3 2 1 Product Dimensions Figure 2 shows the overall view of the Tattile device dimensions in millimeters Figure 2 Tattile VEGA1 dimen...

Страница 13: ...l Characteristics RMM_00053_02 13 38 VEGA1 Series 3 2 2 Wall Mount Bracket Dimensions Figure 3 shows the overall view of the wall mount bracket dimensions in millimeters Figure 3 Wall mount bracket di...

Страница 14: ...view Figure 4 Product overview Ref Description 1 OCR camera ANPR image 2 Infrared illuminator 3 Context camera Overview image 4 Back cover 5 Camera housing 6 Lens hood sun shield 7 Mounting bracket 8...

Страница 15: ...nput 24 Vdc E GNDS RS422 485 serial port ground F IN0 Digital input 0 positive G IN0 1 COM Digital input 0 1 Common negative H OUT0 NO Relay Output 0 NO contact J OUT0 COM Relay Output 0 COM contact K...

Страница 16: ...NP Channels 2 Auxiliary Connector Voltage 24 Vdc Table 5 Input Interface Figure 6 Input schematic section Relay Output Feature Description Type Normally open Channels 2 Auxiliary Connector Max switchi...

Страница 17: ...rrent 50 mA Table 7 Strobe Interface Figure 8 Strobe schematic section 3 3 3 Gigabit Ethernet Connector The type of the Gigabit Ethernet connector is Jam nut RJ 45 IP68 Mating part included in the pac...

Страница 18: ...idity sensor Power supply voltage and current monitoring sensor Real time clock GPS Optional Wi Fi Optional Optional Features Model Recognition Class Recognition Brand Recognition Color recognition OC...

Страница 19: ...ce Max vehicle speed 200 km h Detection 99 Reading 95 OCR ANPR on board engine 2nd Level OCR optional Capture rate Up to 60 fps AES256 Yes SHA2 Yes Compression JPG Configuration Web Server Installatio...

Страница 20: ...Product label Part Description 1 Company logo 2 Product name 3 Mac Address number barcode code 128 4 Mac Address number 5 Serial number barcode code 128 6 Product serial number 7 Product part number...

Страница 21: ...al system EMC EN55022 emission class B EN61000 4 2 ESD 6 kV contact 8 kV Air EN61000 4 3 RF radiated 20 V m AM 1 kHz 80 80 1000 MHz 20 V m AM 1kHz 80 1 6 GHz 10 Veff m PM 50 200Hz 900 MHz 1890 MHz EN6...

Страница 22: ...an radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interferen...

Страница 23: ...le mounting adaptor cod T19841 Horizontal pole adaptor kit cod T19943 The pole mounting bracket is only required when you need to install the product on a pole with dimensions between 65 mm and 110 mm...

Страница 24: ...mm length Figure 12 Cable and Conductor insulation removing 2 Crimp or solder the PIN on the bare copper of each conductor Be sure to correctly crimp the copper Never leave bare copper 3 Dismount the...

Страница 25: ...ed use an external junction box because only one cable must be inserted into the connector Figure 13 Correct Backshell Mounting Important advices The junction box and the cable that connects the remot...

Страница 26: ...orrect pins The conductors are now available for use 4 4 3 Cabling the Ethernet Connector This procedure is useful to cable the device to the network This chapter shows how to connect the Plug connect...

Страница 27: ...to the bottom and the outer jacket of the cable secured to the connector by the jacket clamp B Figure 17 Crimping Plug RJ 45 5 Insert the Plug RJ 45 into mating Connector 6 Tighten the nut to rear of...

Страница 28: ...that employ switching technology Install the device and cables as far as possible from devices generating sparks Make sure The device is correctly cabled The IP address of the device is available A PC...

Страница 29: ...ounting 4 5 3 Horizontal pole mounting 1 Fix the wall mount bracket to the bottom of the device with 4 screws type M6 included in the package with a torque of 8 Nm 2 Fix the pole mounting adaptor to t...

Страница 30: ...best focus parameter 6 Cable the device and connect the device to a PC 7 Start up the device After about 60 seconds the operating system is ready for use 8 Search for the device using the specific co...

Страница 31: ...re tool Tattile Pathfinder to search for a device The device is now available for use For more information on the freeware software tool Tattile Pathfinder read and follow the user manual of the produ...

Страница 32: ...are software tool Tattile Pathfinder to search for the desired device The default IP address of the device is 192 168 0 21 3 Modify the IP address of the device The device is now available for use The...

Страница 33: ...parameters Modify the default login credentials of the web interface Modify the IP address of the device Check the device correct aiming Check that the device is able to read a car plate positioned on...

Страница 34: ...ask of user s PC Modify the IP address of the device or of the PC The PC is configured for DHCP IP assignment Define a static IP address to the PC belonging to the host address of the device The web i...

Страница 35: ...12 months In case of damages to cables substitute cables with a new product 7 2 Cleaning the Protection Glass Use a wet soft cloth or a microfiber cloth to clean the protection glass every 12 months o...

Страница 36: ...daptor Order Code Description T19841 Pole mounting adaptor for poles with diameter between 65 mm and 110 mm 4 Figure 21 Vertical pole mounting adaptor 8 2 Horizontal Pole Adaptor Order Code Descriptio...

Страница 37: ...Series 8 3 Power Supply Order Code Description F01836 Power Supply In 100 240Vac 50 60Hz Out 24Vdc 5A 8 4 Connectors Mating Parts Kit Order Code Description T20447 Mating parts kit for Power I O Ethe...

Страница 38: ...Romano L Bonisoli 01 2019 11 04 General revision Update Technical Sheet Specifications Update with details and images Chap 4 Preparation Installation Modification dimension of Base of Wall mount brack...