2-2. Installation
1. Shut off power to the dispenser before starting the nozzle & swivel installation or replacement. Relieve
system pressure before servicing or replacing.
2. Carefully drain fuel from hose & nozzle & swivel into approved container in the case of replacing nozzles.
3. If nozzle & swivel replacement, Replace the O-ring of the hose side with new.
The tightening torque of the screw: 60N.m.
4. Flow test nozzles & swivels before putting nozzles & swivels in service.
See testing instructions. (Reference page 4)
WARNING
1. Please read safety instructions "HINTS AND TIPS FOR SAFE USE" completely before installing and
replacing nozzles.
2. Discharge your static electricity before installing.
Static electricity may ignite gasoline vapours.
3. Not to mix rubbishes into the nozzle when installing and replacing
nozzles. This could result in foreign material in the nozzle’s main valve
and cause the nozzle to not shut off.