14/02/05
5
2.
Setup
There are various MODES accessible via SETUP:
They are entered via. the FUNCT or “function” button and modified by the SEL or “select”
button.
NOTE: No key press for 2 seconds will accept the value displayed and return to the normal display.
FUNCT; the Yellow button.
If this button is held down the audio is silent. If held down for more than one second a BELL
will be heard and the current value display will be blank. The Digit display will now be a
“SETUP” screen. Now release the key.
Each “TAP” of the FUNCT key will cycle through the
modes from 1-4.
MODE 1 - average display:
The screen will show
F
or
SL
F-
(fast) The digit display will show the current
value (see mode 3).
SL-
(slow)
The digit display will show a 20 second
average value
TAP “SEL” to toggle.
TAP FUNCT
MODE 2 - full scale set:
The screen will show 5 or 1
0
10- The current value display is +/-0-10 FSD.
5
-
The current value display is +/-0-5 FSD.
Note: m/s units display 2.5 or 5.0 FSD
TAP “SEL” to toggle
Note: The average display will not change.
TAP FUNCT
MODE3 - response time:
The screen will show
r1-7.
1
=1sec response time and it is incremented by
0.5 sec.
ie.
r3
=2 second response
TAP FUNCT
MODE 4 - tone on sink on/off:
The screen will show
t1
or
t2
t1
tone on climb only.
t2
tone on climb and sink
TAP “SELECT” to toggle