TASKING iSYSTEM RH850 Скачать руководство пользователя страница 13

Accessories

Analog/Digital and Network Trace

Ordering Code

Description

IC57031

IOM6 Hub (3 x FNet & FBridge)

IC57040

IOM6 CAN/LIN

IC57041

IOM6 ADIO

IC57125-1

ARM HSSTP II Active Probe

IC57163-1

Infineon DAP/DAPE II Active Probe

IC57164

Infineon AGBT Active Probe

IC57150

MPC5x/SPC5x Aurora Active Probe

IC57166

Infineon SGBT (HSTCU) Active Probe

RH850 Aurora Active Probe Accessories

Ordering Code

Description 

BB-FNET-100

1.0m FNet Cable

BB-FNET-300

3.0m FNet Cable

BB-FNET-500

5.0m FNet Cable

IASAM34MPCPIN14

14-pin 2.54 mm JTAG Adapter

BB-AP-MDIO-20

mDIO Cable

Please refer to the iC5700 BlueBox for all current iC5700 Accessories.

More information about our products on 

www.isystem.com

 or via 

[email protected]

.

Содержание iSYSTEM RH850

Страница 1: ...RH850 Aurora Active Probe User Manual V1 4 September 2023 isystem com start...

Страница 2: ...otential damage caused by any voltage difference between the device and the target system Use proper overvoltage protection Ensure proper protection to avoid exposing the BlueBox device or the operato...

Страница 3: ...850 Aurora Active Probe 4 Specifications 5 Operation 6 mDIO Cable 8 14 pin 2 54 mm LPD Adapter 9 RH850 Aurora 34 pin to Aurora 46 pin Converter 10 Hardware Setup and Configuration 12 Accessories 13 Us...

Страница 4: ...interface operating at its maximum frequency Its small and compact hardware size allows for connecting to a target microcontroller in a confined space as far as 10 m away The Active Probe supports up...

Страница 5: ...ATION Communication interface to BlueBox iSYSTEM proprietary FNet Debug signal valid input voltage range 3 3V max 3 6V Power consumption Max 1 5W dependent on operation mode Number of supported AGBT l...

Страница 6: ...nput O Ground GND 17 18 nEVTO Nexus Event Output I Reserved 19 20 FLMD1 Flash Mode Reserved 21 22 RESETn Reset I O Ground GND 23 24 GND Ground Not Connected NC 25 26 CLK_P AGBT Clock_P O Not Connected...

Страница 7: ...use Blinking green Establishing connection with the BlueBox Blinking blue Reprogramming SPLASH Permanently magenta Golden image loaded and ready to use D FNet connector that connects the Active Probe...

Страница 8: ...controlled by the debugger For example the debugger can periodically service an external watchdog through the mDIO output or just read and record an external signal through the mDIO input It must be o...

Страница 9: ...Ordering code IC57176 The following pinout is valid on the target side Signal Direction Signal Description Signal Pin Pin Signal Signal Description Signal Direction O LPD LPDCLK 1 2 GND Ground O JTAG...

Страница 10: ...RESET Debug Signal Reserved 9 10 NC Not Connected Ground GND 11 12 nTRST JTAG O Reserved 13 14 FLMD0 Flash Mode O Reserved 15 16 nEVTI Nexus Event Input O Ground GND 17 18 nEVTO Nexus Event Output I R...

Страница 11: ...GND 11 12 nTRST Debug Signal O Reserved 13 14 FLMD0 Flash Mode O Reserved 15 16 nEVTI Nexus Event Input O Ground GND 17 18 nEVTO Nexus Event Output I Reserved 19 20 FLMD1 Flash Mode Reserved 21 22 nRE...

Страница 12: ...V even before any of the devices are powered up This voltage difference is discharged over the BlueBox and the Target leading to the possible destruction of electronic components 4 Connect FNet cable...

Страница 13: ...Probe IC57150 MPC5x SPC5x Aurora Active Probe IC57166 Infineon SGBT HSTCU Active Probe RH850 Aurora Active Probe Accessories Ordering Code Description BB FNET 100 1 0m FNet Cable BB FNET 300 3 0m FNet...

Страница 14: ...User Notes This page is intentionally left blank...

Страница 15: ...This page is intentionally left blank...

Страница 16: ...www isystem com Visit our website for Support isystem com support Tutorials isystem com start Knowledge Base kb isystem com...

Отзывы: