11
I25
I24
I23
I22
I21
I20
I19
I18
I17
I16
I15
I14
I13
I12
I11
I10
I9
I8
I7
tr
pt
it
fr
en
de
Preparation for operation/Operation
Attaching tools
Check:
• that the tools are not below the red marking and that the bristle length is not
less than 1 cm.
• the pad for wear before using.
Attach squeegee
Filling water
Dosage:
Only use chemical products recommended by the manufacturer.
The dosing aid is marked for a 0.5% cleaning solution.
The level indicators on the tank correspond to those on the dosing aid. The
machine type is noted on the dosing aid!
Dosing examples (The concentration is product dependent)
Beginning work
• Switch the machine off and pull the power supply cord out of the mains
socket.
Working with worn out, damaged and or wrong tools, could result
in possible damage to floors or their protective layers.
• Position the tool below the brush unit.
• Plug the power supply cord into the mains socket.
• Switch the machine on (main switch and mains
socket).
The main switch lights up.
• Unlatch the foot lever and slowly lower the tool.
• Briefly pull the brush drive bar.
By doing this the tool will be centered and coupled.
Moving the machine forwards and backwards slightly as the brush
unit lowers, makes coupling easier.
• Switch the machine off.
• Raise the squeegee and loosen the fixing
screws on the squeegee.
• Assemble the squeegee and tighten the fixation
knobs.
• Attach the suction hose to the squeegee.
Caution:
Maximum permissible water temperature 60 °C/140 °F.
• Switch the machine off and pull the power supply cord out of the mains
socket.
• Reach into the opening between the tank lid and
the tank.
Palm facing upwards.
• Open the lid until the self support locates on the tank wall.
• Remove the dosing aid.
• Fill water into the solution tank.
Maximum permissible filling level (Page 10).
Caution:
Wear protective gloves, goggles and the corresponding
(protective) work clothing when handling chemical products!
Caution:
Using other chemicals (e.g. chemicals containing solvents,
chlorine, hydrochloric acid and hydrofluoric acid) can damage or
destroy the machine.
Dosage
Tank capacity
Dosing aid
0,5%
1/2
1 x 1/2
MAX
1 x MAX
1%
1/2
1 x MAX (2 x 1/2)
MAX
2 x MAX
• Dosing aid application
• Add the product measured with the dosing aid to the water in the solution
tank.
• Lift the tank lid slightly.
• Gently press the self support inwards.
• Close the lid.
• By exerting slight pressure onto the front part of the lid, you can click it into
the latch.
Caution:
Always wear non-slip shoes and appropriate work clothing while
working with this machine!
• Lower the squeegee.
• Plug the power supply cord into the mains socket.
• Switch the machine on (main switch and mains
socket).
The main switch lights up.
• Lower the brush unit using the brush unit pedal, refer to Page 11.
• First press the cleaning solution switch, and
then the suction unit switch.
The switches light up.
max.60
˚
C
max.140
˚
F