66
Malfunctions
Technical data
Accessories
Malfunction
Possible causes
Troubleshooting
Page
Machine without function
Machine is switched off
• Switch on the main switch
No power supply
• Insert the plug into the mains sock
-
et
Main cord defect
• Replace the main cord
Motor does not turn
• Contact your service partner
Foot pedal is locked
Unlock the foot pedal
Defective safety switch
• Contact your service partner
Pad does not turn
Motor runs, but tool does not rotate
• Drive belt torn or loose
• Contact your service partner
Defective electronic component
• Contact your service partner
Machine has no function, indicator
light is on
Machine overload, overload switch
was activated
• Wait a few minutes and try again
(overload switch resets automati
-
cally)
Machine does not reach nominal
speed, overcurrent is activated
Machine overload
• Check the work technique
Undervoltage: Main cord is too long
• Remove power supply cord exten
-
sion
• Check the voltage rating
Machine does not run smoothly
Pad deformed or damaged
• Replace pad
Machine
ergodisc 2000
Working width
50
cm
Dimensions (LxWxH)
108 x 59 x 119
cm
Maximum weight of operational machine
54
kg
Rated voltage
220-240V~
100-120V~
220V~
AC
Frequency
50
60
60
Hz
Rated power, nominal
1500
W
Values according to IEC 60335-2-67
Sound pressure level LpA
68
dB(A)
Uncertainty KpA
2.5
dB(A)
Vibration
<2.5
m/s2
Uncertainty K
0.25
m/s2
Splash water guard
IPX0
Protection class
I
No.
Item
7521297
One-way fleece dust bag
Various pads (pink, red or special pads)