![TASKalfa 3500i Скачать руководство пользователя страница 105](http://html1.mh-extra.com/html/taskalfa/3500i/3500i_troubleshooting-manual_3651273105.webp)
23.Install the fuser unit and drive it to check if the abnormal ticking sound is heard.
The latch of the bearing to the frame may still not be released in case any abnormal sound is heard.
Perform the procedures No.1 and after again.
Move the frame in the procedures No 6- 10 cycles
Note) Move the frame to the left and right after removing the screw (No.6) that is added this time.
Abnormal sound from the fuser section (5/5)
For 3500i/4500i/5500i
105