background image

©Copyright Task Force Tips LLC   2018 - 2019 

LIS-045 April 22, 2019 Rev01

5

3.0  GENERAL INFORMATION

The TFT VORTEX ER Nozzles enhance the use of smoothbore nozzles. They are intended for installation behind a smooth bore 
nozzle for use with water or fi re fi ghting foam solutions. Six short vanes in the bore of the VORTEX reduce turbulence in straight 
stream. Actuating a VORTEX ER Nozzle from “STREAM” to “VORTEX” causes the vanes to pivot proportionally. This induces a 
gentle spin in the water to create a uniformly dispersed VORTEX stream pattern. The vanes are less obtrusive than a typical stream 
straightener, resulting in virtually no friction loss regardless of which stream pattern is selected. The vanes also allow large debris to 
easily pass through the VORTEX. Pattern selection is controlled with an electric drive on VORTEX ER nozzles. 

A manual actuation crank turned by hand is used to change the pattern on manually operated versions.

3.1  PART IDENTIFICATION AND TERMS
3.1.1  VORTEX 2 AND 2 ER PART IDENTIFICATION AND TERMS

VORTEX 2 & 2 ER models are confi gured with a 2.5” female coupling and 2.5” male threads on the outlet for use with stacked tips.

MANUAL ACTIVATION
CRANK

INLET COUPLING

OUTLET THREADS

SERIAL NUMBER

ACTUATOR WITH MANUAL OVERIDE 5/16" HEX

WARNING
LABEL

VORTEX 2 ER

VORTEX 2

Figure 3.1.1 

VORTEX 2 ER and VORTEX 2 Part Identifi cation and Terms

3.1.2  VORTEX 6 ER PART IDENTIFICATION AND TERMS

VORTEX and VORTEX ER models are confi gured with a 6”NH female fi xed coupling and 6”NH male threads on the outlet for use 
with connecting to Tsunami Stacked Tips. 

INLET COUPLING
FOR CONNECTING 
TO QUICK CONNECT
OUTLET OF TSUNAMI 
STACKED TIPS 
(YST-8NX)

OUTLET THREADS 
FOR CONNECTING
TSUNAMI
STACKED TIPS 
(YST-8NX)

SERIAL NUMBER

ELECTRICAL
QUICK CONNECT
FOR TFT MONITORS

ACTUATOR

WARNING
LABEL

MANUAL OVERIDE
5/16” HEX

SVX130L

MADE IN USA • tft.com

®

Understand manual before use

Obtain safety information at 

tft.com/serial-number

WARNING

PATENT PENDING

VORTEX

TM

VORTEX

STREAM

Figure 3.1.2 

VORTEX 6 ER Part Identifi cation and Terms

Содержание VORTEX 2 ER

Страница 1: ...use of this equipment Obtain safety information at tft com serial number This instruction manual is intended to familiarize re ghters and maintenance personnel with the operation servicing and safety...

Страница 2: ...ent you may be called upon to use 3 It is your responsibility to know that you have been properly trained in Fire ghting and or Emergency Response and in the use precautions and care of any equipment...

Страница 3: ...4 0 FLOW CHARACTERISTICS AND CHARTS 7 4 1 VORTEX 2 2 ER FLOW CHARACTERISTICS AND CHARTS 4 2 VORTEX 6 ER FLOW CHARACTERISTICS AND CHARTS 5 0 INSTALLATION 9 5 1 VORTEX 2 2 ER INSTALLATION 5 2 VORTEX 6...

Страница 4: ...is intended for use by trained personnel for re ghting Their use for other purposes may involve hazards not addressed by this manual Seek appropriate guidance and training to reduce risk of injury WA...

Страница 5: ...ually operated versions 3 1 PART IDENTIFICATION AND TERMS 3 1 1 VORTEX 2 AND 2 ER PART IDENTIFICATION AND TERMS VORTEX 2 2 ER models are con gured with a 2 5 female coupling and 2 5 male threads on th...

Страница 6: ...hly cleaned with fresh water after each use The service life of the nozzle may be shortened due to the e ects of corrosion and is not covered under warranty 3 2 SPECIFICATIONS Model VORTEX 2 VORTEX 2...

Страница 7: ...0 375 500 625 750 875 1000 1125 1250 Flow gpm 1 0 Tip 1 25 Tip 1 5 Tip 1 75 Tip 25 mm 32 mm 35 mm 38 mm 44 mm 2 0 Tip 51 mm Figure 4 1A 2 5 Waterway Flow Chart Nozzle Diameter inches Nozzle Pressure P...

Страница 8: ...5 Tip 130 mm 0 25 50 75 100 125 150 175 200 Figure 4 2A 6 157mm Waterway Flow Chart Nozzle Diameter inches Nozzle Pressure PSI 50 60 80 100 Flow GPM Reaction lbf Flow GPM Reaction lbf Flow GPM Reactio...

Страница 9: ...5 45mm 1 5 38mm 1 375 35mm 2 00 50mm MST 4NJ 4 Stacked Tips MST 3NJ 3 Stacked Tips Figure 5 1 VORTEX 2 VORTEX 2 ER Installation 5 2 VORTEX 6 ER INSTALLATION The VORTEX 6 ER is intended to be installed...

Страница 10: ...until reaching the full VORTEX pattern shown in gure 6 0D VORTEX STREAM VORTEX STREAM Straight Stream Dispersed Pattern Figure 6 0C Straight Stream pattern setting Figure 6 0D Full VORTEX pattern sett...

Страница 11: ...n the foam stream can cause a break in the foam blanket and greatly increase the risk of injury or death Assure that Application rate is su cient see NFPA 11 or foam manufacturer s recommendations Eno...

Страница 12: ...W 3 VT10 32SH375 7 SHAPER 1 SVJ120 8 10 32 X 1 2 SOCKET HEAD CAP SCREW 1 VT10 32SH500 9 ACTUATOR VORTEX ER 1 Y7210 ACTUATOR VORTEX MANUAL Y7220 10 GEARBOX LABEL VORTEX 1 SVX130L 11 10 32 X 3 4 SOCKET...

Страница 13: ...7 5 1 4 20 X 3 4 SOCKET HEAD CAP SCREW 3 VT25 20SH750 6 10 32 X 1 0 SOCKET HEAD CAP SCREW 2 VT10 32SH1 0 7 GEARBOX LABEL VORTEX 1 SVX130L 8 10 32 X 1 1 4 SOCKET HEAD CAP SCREW 2 VT10 32SH1 2 9 VANE BU...

Страница 14: ...er which if so desired can be used to identify nozzle for documentation purposes The following information if applicable must be included on the test record for each nozzle 1 Assigned identification n...

Страница 15: ...rge of its obligations under this limited warranty If TFT makes this election claimant shall return the equipment to TFT free and clear of any liens and encumbrances This is a limited warranty The ori...

Страница 16: ...ozzles must be inspected to this checklist 1 All controls and adjustments are operational 2 There are no broken or missing parts 3 There is no damage to the nozzle that could impair safe operation e g...