![Task Force Tips Typhoon Series Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/task-force-tips/typhoon-series/typhoon-series_instructions-for-installation-safe-operation-and-maintenance_3681021014.webp)
©Copyright Task Force Tips LLC 2004-2020
LIY-050 August 17, 2020 Rev14
14
4.3 INLET FITTING OR EXTEND-A-GUN INSTALLATION
The Typhoon Monitor is available with various inlet fittings. When the inlet fittings are used, see Section 3.5.1 - 3.5.4 for the addition
to overall height.
The Typhoon Monitor also connects directly to TFT’s Extend-A-Gun RC3 or RC4. The fittings and Extend-A-Gun RC are attached to
the monitor by means of a threaded joint with an O-ring seal.
4.4 TWO PIECE CLAMP ROTATIONAL LOCK INSTALLATION
VSA-125
VSA-125
Y4437
VW360x200-04
Y4435
VT10-32SH1.2
Apply VSA-125 blue Loctite to threads on both
Cylinder Nuts.
MONITOR BASE CLAMP
WASHER
SOCKET HEAD SCREW
10-32 X 1-1/4 LONG
CYLINDER NUT
BLUE LOCTITE
BLUE LOCTITE
STEP 1
CYLINDER NUT
HEAD GROOVE
TOP SIDE OF CLAMP
Align grooves in heads of Cylinder Nuts with top
sides of Clamps.
Slide Screws through Washers and Clamps.
Loosely thread Screws into Cylinder Nuts.
STEP 2
EXTEND-A-GUN
MALE OUTLET
THREADS
TOP SIDE
OF CLAMPS
LOOSE CLAMP
ASSEMBLY
CYLINDER
NUT HEAD
Place Clamp assembly over male threads of
outlet.
Cylinder Nut heads MUST be on top side of
Clamps.
STEP 3
Figure 4.4A