Task Force Tips Master Foam Series Скачать руководство пользователя страница 15

©Copyright Task Force Tips LLC 2015-2020

15

LIZ-030 October 29, 2020 Rev13

8.0 MAINTENANCE

TFT  products  are  designed  and  manufactured  to  be  damage  resistant  and  require  minimal  maintenance.  However,  as  the  primary

firefighting tool upon which your life depends, it should be treated accordingly. To help prevent mechanical damage, do not drop or throw

equipment. 

8.1 FIELD LUBRICATION

All Task Force Tips nozzles are factory lubricated with high quality silicone grease. This lubricant has excellent wash out resistance,

providing long term performance in firefighting nozzles. If your agency has unusually hard or sandy water, the moving parts of the nozzle

may be affected. Foam agents and water additives contain soaps and chemicals that may break down the factory lubrication. 
The moving parts of the nozzle should be checked on a regular basis for smooth and free operation, and for signs of damage. IF THE

NOZZLE IS OPERATING CORRECTLY, THEN NO ADDITIONAL LUBRICANT IS NEEDED. Any nozzle that is not operating correctly

should be immediately removed from service. The nozzle can be returned to the factory at any time for a complete checkup and re-

lubrication with silicone grease.
The field use of Break Free CLP (spray or liquid) lubricant will help to temporarily restore the smooth and free operation of the nozzle.

These  lubricants  do  not  have  the  washout  resistance  and  long-term  performance  of  the  silicone  grease.  Once  Break  Free  CLP  is

applied, re-application will be needed on a regular basis until the nozzle can be returned to the factory for a complete checkup and re-

lubrication with silicone grease. 

8.2 SERVICE TESTING

In accordance with NFPA 1962, equipment must be tested a minimum of annually. Units failing any part of this test must be removed

from service, repaired and retested upon completion of the repair. 

8.3 REPAIR

Factory  service  is  available  with  repair  time  seldom  exceeding  one  day  in  our  facility.  Factory  serviced  equipment  is  repaired  by

experienced technicians, wet tested to original specifications, and promptly returned. Any returns should include a note as to the nature

of the problem and whom to reach in case of questions.
Repair parts and service procedures are available for those wishing to perform their own repairs. Task Force Tips assumes no liability for

damage to equipment or injury to personnel that is a result of user service. Contact the factory or visit the web site at tft.com for parts

lists, exploded views, test procedures and troubleshooting guides.  
Performance tests shall be conducted on the equipment after a repair, or anytime a problem is reported to verify operation in accordance

with TFT test procedures. Consult factory for the procedure that corresponds to the model and serial number of the equipment. Any

equipment which fails the related test criteria should be removed from service immediately. Troubleshooting guides are available with

each test procedure or equipment can be returned to the factory for service and testing. 

9.0 EXPLODED VIEWS AND PARTS LISTS

Exploded views and parts lists are available at tft.com/serial-number.

CAUTION

Aerosol lubricants contain solvents that can swell O-Rings if applied in excess. The swelling can 

inhibit smooth operation of the moving parts. When used in moderation, as directed, the solvents 

quickly evaporate without adversely swelling the O-Rings. 

CAUTION

Any alterations to the product or its markings could diminish safety and constitutes a misuse of 

this product. 

NOTICE

All replacement parts must be obtained from the manufacturer to assure proper operation of the 

device. 

Содержание Master Foam Series

Страница 1: ...t shall have completed a course of education approved by the Authority Having Jurisdiction AHJ This instruction manual is intended to familiarize firefighters and maintenance personnel with the operat...

Страница 2: ...ment you may be called upon to use 3 It is your responsibility to know that you have been properly trained in Fire ghting and or Emergency Response and in the use precautions and care of any equipment...

Страница 3: ...vation Refer to LIM 030 and LIM 035 for effective stream trajectories of Task Force Tips Masterstream nozzles at 30 elevation This graph cannot be used to estimate maximum reach for elevation angles b...

Страница 4: ...OUPLINGS 3 5 ELECTRIC INSTALLATION 4 0 OPERATION 4 1 PATTERN CONTROL 4 2 FLUSHING DEBRIS 5 0 USE WITH FOAM 5 1 FOAM ASPIRATING ATTACHMENTS 5 2 CLEANING AFTER USE 5 3 SETTING FOAM PERCENTAGE 5 3 3 ORIF...

Страница 5: ...capable of supporting the nozzle reaction force FLOW REACTION FORCE gpm l min Pounds Kilograms 250 950 132 60 350 1325 185 84 500 1900 265 120 750 2900 397 180 1000 3800 529 240 1250 4800 661 301 1500...

Страница 6: ...ble 3 1 Figure 3 1A RANGE SMALL MEDIUM LARGE INLET COUPLING 2 5 65mm NH NPSH or BSP 3 5 89mm NH NPSH or BSP 3 5 89mm NH 4 0 100mm BSP RATED PRESSURE 100 psi 7bar 100 psi 7bar 100 psi 7bar FLOW RATING...

Страница 7: ...s LLC 2015 2020 7 LIZ 030 October 29 2020 Rev13 Figure 3 1B Figure 3 1C Stream Shaper Baffle Foam Inlet Coupling Serial Number Folding Handles Orifice Plate Override Knob Masterfoam 1000 1250 1500 200...

Страница 8: ...reach Range SMALL MEDIUM LARGE Nominal Flow 250 gpm 950 l min 350 gpm 1325 l min 500 gpm 1900 l min 750 gpm 2900 l min 1000 gpm 3800 l min 1250 gpm 4800 l min 1500 gpm 5700 l min 2000 gpm 7600 l min...

Страница 9: ...e air Generally the straight stream reach with foam is approximately 10 less than with water only Actual results will vary based on brand of foam hardness of water temperature etc For specific informa...

Страница 10: ...mply push it into the bore at the foam inlet on the nozzle The orifice plate has an O ring to hold it in place To remove the orifice plate hook a small object such as a screwdriver or Allen wrench int...

Страница 11: ...BRATION 0 5 and 1 Class A foam of 20 centipoise viscosity 3 3M ATC 3 AR AFFF product code ATC 603 6 3M ATC AFFF product code FC 600F PERCENT 1000 and 1250 gpm Nozzles FOAM USED FOR CALIBRATION 1 Willi...

Страница 12: ...20 40 60 80 100 120 140 160 180 200 220 A B A TFT MASTER FOAM B TFT MASTER FOAM WITH FOAMJET LX 3 or 1 FOAM AT 350 GPM AND 100 PSI Ver cal Distance Feet 0 10 20 30 40 50 60 70 Horizontal Distance Met...

Страница 13: ...0 140 160 180 200 220 240 260 280 300 0 10 20 30 40 50 60 Horizontal Distance Meter Ver cal Distance Meter Horizontal Distance Feet Ver cal Distance Feet 3 or 1 Foam at 1000 GPM 100 PSI 0 10 20 30 40...

Страница 14: ...ge of its obligations under this limited warranty If TFT makes this election claimant shall return the equipment to TFT free and clear of any liens and encumbrances This is a limited warranty The orig...

Страница 15: ...mum of annually Units failing any part of this test must be removed from service repaired and retested upon completion of the repair 8 3 REPAIR Factory service is available with repair time seldom exc...

Страница 16: ...low is adequate as indicated by pump pressure and nozzle reaction BEFORE BEING PLACED BACK IN SERVICE nozzles must be inspected to this checklist 1 All controls and adjustments are operational 2 There...

Отзывы: